PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 10, 2026Ain Shams Engineering Journal0 citationsOpen Access

Noninvasive imaging of small living insects using high-speed phase-contrast CT

View Full Paper
RTRongbiao TangKLKe LiFWFeixiang Wang

Key Points

  • The study aims to evaluate the safety and imaging efficacy of high-speed phase-contrast CT for visualizing living Trichorhina tomentosa insects.
  • Utilized high-speed phase-contrast CT system for imaging
  • Integrated fast-acquisition detector and rapid-rotation sample stage
  • Conducted phase retrieval for quantitative phase information extraction
  • Assessed tissue visibility using signal-to-noise ratio measurements
  • Monitored the viability of specimens post-imaging for one week.
  • Achieved image acquisition speed of 2400 fps and rotation speed of 720°/s
  • CT scans completed in 250 ms with 600 projections per scan
  • TT specimens remained viable post-imaging, confirming the safety of the method
  • Showed clear visualization of anatomical structures for dimensional measurements
  • Absorbed irradiation dose ranged from 371 to 380 mGy per CT scan.

Abstract

Noninvasive visualization of intact, living insects marks an important methodological advance for research in entomology, ecology, and environmental science. In this study, we investigated the safety and imaging efficacy of high-speed phase-contrast CT (PCCT) for visualizing living Trichorhina tomentosa (TT). TT is a widely distributed group of small insect organisms in natural environments. Using TT as a model organism for live imaging studies holds broad biological significance, as it offers valuable real-time insights into fundamental entomological functions, species-specific ecological adaptations, and organism-environment interactions under realistic conditions. A high-speed PCCT system that integrated a fast-acquisition detector, a rapid-rotation sample stage, and a quick-action shutter was employed. The image acquisition speed of the detector was set to 2400 fps, and the sample stage rotated at a speed of 720°/s. The shutter operated with high efficiency, achieving full opening or closing in 3 ms. Each CT scan, which consisted of 600 projections of TT, was completed in 250 ms, covering a 180° rotation. Initial projection data underwent phase retrieval (PR) via the phase-attenuation duality method to extract quantitative phase information. Tissue visibility was quantitatively assessed using the signal-to-noise ratio (SNR). The absorbed irradiation dose (AID) in one CT scan ranged from 371 to 380 mGy. The TT specimens remained viable and in good condition throughout a week of post-imaging monitoring, underscoring both the high safety profile and physiological compatibility of the PCCT system. The anatomical structures of the TT body were clearly visualized, allowing for reliable dimensional measurements. Our findings demonstrate that the high-speed PCCT system holds considerable potential for the noninvasive in vivo visualization of small living insects possessing radiation tolerance that meets or exceeds currently applied dose levels.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tang et al. (2026) studied this question.

synapsesocial.com/papers/69af94e870916d39fea4bf85https://doi.org/10.1016/j.asej.2026.104073
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Imaging intact human organs with local resolution of cellular structures using hierarchical phase-contrast tomography2021 · 325 citations
  2. 2Noninvasive, label-free visualization of living killifish embryos using high-speed phase-contrast CT2025 · 2 citations
  3. 3Multiscale X-ray phase-contrast CT unveils the evolution of bile infarct in obstructive biliary disease2024 · 6 citations
  4. 4High-speed, two-dimensional synchrotron white-beam x-ray radiography of spray breakup and atomization2017 · 34 citations
  5. 5Computerized Classification Systemfor the Identification of Soil Microorganisms2016 · 7 citations