PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 10, 2026Journal of Ultrasound in Medicine1 citationsOpen Access

Feasibility of Imaging the Uvula at the Midtrimester Anomaly Ultrasound

View Full Paper
ASAnna Rose SimsStellenbosch UniversityLPL. R. PistoriusStellenbosch UniversityDSDenise SproulWestern Cape Department of Health

Key Points

  • The study aims to assess whether imaging the uvula using the equal sign in midtrimester ultrasounds is feasible.
  • Retrospective audit of ultrasound practices in Cape Town, South Africa.
  • Included women with singleton pregnancies undergoing routine anomaly ultrasounds.
  • Visualized the equal sign during examinations of the face or brain.
  • The equal sign was visualized in 97% of randomly selected cases.
  • Visualized sequencing occurred in 88% while examining the face or brain.
  • Mean time for visualization was 28 seconds with a 1.5% increase in total scan time.
  • No false positive diagnoses were reported for abnormal uvula.

Abstract

Objectives The fetal palate is not routinely imaged as part of the midtrimester fetal anomaly ultrasound, despite being associated with many syndromes. The “equal sign” depicts the lateral borders of the uvula on 2‐dimensional fetal ultrasound. We assessed the feasibility of adding the equal sign to the midtrimester fetal anomaly ultrasound. Methods A retrospective audit of an ultrasound practice in Cape Town, South Africa was performed. Women with singleton pregnancies presenting for a routine anomaly ultrasound between October 2013 and September 2019 were included. Results A total of 5301 ultrasound examinations were performed during the time period. In a sample of 101 cases selected randomly, the equal sign was clearly visualized in 97% (98/101) of cases. It was visualized in sequence while examining the face or brain in 88% (89/101). Mean time to visualize the equal sign was 28 seconds. Total scan time increased by 1.5%. The body mass index had no effect on detection rate. Of the 5301 scans performed during the study period, there were 15 cases where the uvula was abnormal. Ten of these 15 cases had an intact lip. There were no false positive diagnoses of an abnormal uvula. Conclusions It is feasible to image the equal sign at the midtrimester ultrasound with a low false positive detection rate.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Sims et al. (2026) studied this question.

synapsesocial.com/papers/69af954870916d39fea4caf7https://doi.org/10.1002/jum.70221
Ask AI
Helpful
Bookmark
Share
View Full Paper