PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 12, 20260 citations

Acoustic Monitoring of Lubrication and Compaction Effects on Tablet Performance Using Broadband Acoustic Resonance Dissolution Spectroscopy.

View Full Paper
RPRaghu V. G. PeddapatlaMAM Rizwan AhmedMSMaria J Sousa-Gallagher

Key Points

  • The aim is to investigate how lubrication and compaction affect tablet performance using the BARDS technique.
  • Monitored tablet behavior in water using BARDS
  • Tested tablets with 10% metoclopramide HCl and microcrystalline cellulose filler
  • Compared lubricated tablets (0.5% magnesium stearate) to unlubricated tablets
  • Calculated areas under the total gas volume and volume curve (AUVC)
  • Analyzed gas elimination kinetics during dissolution.
  • Lubricated tablets exhibited a greater AUVC than unlubricated ones
  • BARDS profiles indicated slower wetting for lubricated tablets
  • Unlubricated tablets showed first-order kinetics at lower pressures
  • Lubricated tablets displayed two phases of gas elimination kinetics compared to unlubricated.

Abstract

Broadband Acoustic Resonance Dissolution Spectroscopy (BARDS) is a novel analytical technology based on the change in the acoustic phenomena observed when a material is added into a solvent. Addition of a solid material results in the introduction of air (gas) into the solvent, which changes the compressibility of the liquid system and reduces the velocity of the sound (resonance) contained therein. In this study, the behavior of tablets in water was monitored using the BARDS technique. Tablets investigated contained 10% metoclopramide HCl (model water-soluble drug) and a microcrystalline cellulose filler and were formulated with and without a lubricant (0.5% magnesium stearate) at a range of tensile strength and porosity properties. The BARDS frequency-time profile for lubricated tablets showed an extended profile, indicating a slower wetting and prolonged displacement of gas compared to those of tablets without a lubricant. BARDS frequency-time profiles were transformed into gas volume-time profiles from which the areas under the total gas volume and volume curve (AUVC) were calculated. Lubricated tablets displayed a greater AUVC compared with unlubricated tablets. A decrease in the AUVC was observed for tablets up to the yield pressure of the formulation. For unlubricated tablets compacted at lower pressures, the gas elimination phase displayed first-order rate elimination kinetics. However, for lubricated tablets and unlubricated tablets compacted at higher pressures, two phases of gas elimination were observed: an initial fast elimination phase followed by a slower terminal elimination phase. This preliminary analysis of BARDS profiles collected demonstrates the capability of BARDS to capture differences between tablet formulations manufactured under different conditions.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Peddapatla et al. (2026) studied this question.

synapsesocial.com/papers/69b257a296eeacc4fcec6636https://doi.org/10.1021/acs.molpharmaceut.5c01170
Ask AI
Helpful
Bookmark
Share
View Full Paper