PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 12, 2026Review of Scientific Instruments0 citations

High performance two-dimensional photon-counting imaging detector based on delay line anode

View Full Paper
YZYalong ZhangYLYongan LiuXYXin Yang

Key Points

  • The aim is to develop a high-performance photon-counting imaging detector using a specific anode design for improved resolution and counting speed.
  • Proposed a microchannel plate detector with a cross-delay-line anode readout.
  • Converted spatial information into temporal signals processed by a high-speed time-to-digital converter.
  • Evaluated performance metrics including spatial resolution, counting rate, and timing accuracy.
  • Achieved spatial resolution better than 70 μm.
  • Maximum counting rate reached 1 MHz.
  • Single-channel timing accuracy demonstrated below 26 ps.
  • Encoding system showed differential nonlinearity and integral nonlinearity below 0.22 and 2.29 LSB respectively.

Abstract

A microchannel plate detector based on a direct-collection cross-delay-line (XDL) anode readout is proposed. By converting spatial information into temporal signals and processing them with a high-speed time-to-digital converter, the system achieves a balance between high spatial resolution and high counting rate. The article elaborates on the detector's design principles, image encoding system, and signal processing workflow. Experimental evaluations were conducted on key performance metrics, including the XDL encoding system's nonlinearity, timing accuracy, as well as the overall spatial resolution and maximum counting rate of the detector. Test results demonstrate that the detector exhibits a spatial resolution better than 70 μm, a maximum counting rate of 1 MHz, and excellent timing precision (single-channel accuracy <26 ps). The encoding system exhibits good linearity with differential nonlinearity and integral nonlinearity below 0.22 and 2.29 LSB (least significant bit). The system is suitable for applications requiring high spatiotemporal resolution, such as particle detection, beam diagnostics, ultraviolet astronomy, and radiation imaging. Future work will focus on upgrading the data transmission interface and optimizing the electronic design to further enhance system performance.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zhang et al. (2026) studied this question.

synapsesocial.com/papers/69b258a396eeacc4fcec8858https://doi.org/10.1063/5.0299830
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Two-dimensional photon counter for x-ray imaging1988 · 3 citations
  2. 2Scintillator–single-photon avalanche diode array-based energy resolving photon counting X-ray detector2024 · 3 citations
  3. 3CCD-based X-ray area detector for time-resolved diffraction experiments2004 · 21 citations
  4. 4Using a 4-Megapixel Hybrid Photon Counting Detector for Fast, Laboratory-Based Nanoscale X-Ray Tomography2026 · 1 citations
  5. 5Modeling and Analysis of a Long-Range Target Localization Problem Based on an XS Anode Single-Photon Detector2024 · 2 citations