PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 12, 20260 citations

Stability Indicating Reverse Phase High-Performance Liquid Chromatographic Method of Isoliquiritigenin: Development, Validation, and Forced Degradation Studies.

View Full Paper
AAAbul Barkat M D Tufail AhmedVHVancha HarishSMSharfuddin Mohd

Key Points

  • To develop and validate a stability-indicating RP-HPLC method for estimating isoliquiritigenin and assessing its stability under stress conditions.
  • Developed RP-HPLC method with isocratic elution on C18 column
  • Used 0.1% v/v formic acid and acetonitrile as mobile phase
  • Conducted forced degradation studies under acid, alkaline, oxidative, thermal, and UV stress
  • Validated according to ICH Q2(R2) guidelines
  • Method showed linearity in 2-10 μg/mL range (R = 0.9985)
  • High accuracy with 98.38%-99.48% recovery
  • Quantification limit: 1.81 μg/mL; detection limit: 0.66 μg/mL
  • ISL degradation was minimal under thermal and photolytic stress, but significantly high under alkaline (93.40%), acidic (98.76%), and oxidative stress (63.80%) at 70°C.

Abstract

A simple, stability-indicating RP-HPLC method was developed to estimate isoliquiritigenin (ISL) and assess its stability under acid, alkaline, oxidative, thermal, and UV stress conditions. Chromatographic separation was performed on a C18 column using UV-visible detection and a 20 μL injection volume, applying an isocratic elution approach to develop and optimize a method for quantifying ISL in stressed samples. At a constant flow rate of 1 mL/min, the mobile phase consisted of 0.1% v/v formic acid (aqueous) and acetonitrile (organic) in a 25:75 ratio. The maximum absorption wavelength (λmax) of ISL was found to be 361 nm. According to ICH Q2(R2) guidelines, the method was validated and showed linearity in the 2-10 μg/mL range (R = 0.9985) with high accuracy (98.38%-99.48% recovery) and precision (% RSD < 2%). Quantification and detection limits were 1.81 and 0.66 μg/mL, respectively. According to forced degradation testing, there was very little deterioration when subjected to thermal and photolytic stress, but there was considerable degradation when exposed to alkaline (93.40%), acidic (98.76%), and oxidative stress (63.80%) at 70°C. The developed method effectively evaluates ISL stability in both bulk and stressed conditions, supporting its use in routine quality control and pharmaceutical formulation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ahmed et al. (2026) studied this question.

synapsesocial.com/papers/69b25b0996eeacc4fcec9670https://doi.org/10.1002/bmc.70422
Ask AI
Helpful
Bookmark
Share
View Full Paper