March 13, 2026IET Science Measurement & Technology0 citationsOpen Access

Development of a Compact Bipolar Voltage Generator to Test HV XLPE Cables With Damped AC Voltage

View Full Paper
JCJunbai ChenKZKun ZhaoYYYu Yan

Key Points

  • This research aims to create a compact bipolar high-voltage direct current generator for better partial discharge testing of XLPE cables.
  • Proposed a bipolar HVDC generator using a modified voltage multiplier
  • Employed bidirectional rectifier switches for voltage polarity control
  • Constructed a three-stage prototype capable of 180 kV
  • Conducted laboratory and field tests to validate system effectiveness
  • Achieved an 80% reduction in space charge accumulation with bipolar DAC voltage
  • Successfully validated the prototype on a lumped capacitor and 110 kV XLPE cable
  • Maintained compactness and portability similar to conventional DAC systems

Abstract

ABSTRACT The damped alternating current (DAC) technique has been widely applied for partial discharge (PD) testing of high‐voltage (HV) cross‐linked polyethylene (XLPE) cables. However, for transmission applications, the unipolar DC charging stage required in conventional DAC systems leads to space charge accumulation, which deteriorates the cable insulation condition. CIGRE TB 841, therefore, recommends the use of a bipolar charging manner instead of the unipolar manner. To address this requirement, a compact bipolar HVDC generator based on a modified voltage multiplier is proposed. In the proposed design, bidirectional rectifier switches are employed in place of unidirectional diode stacks to enable flexible polarity switching of the output voltage. Simulation results demonstrate an 80% reduction in space charge accumulation under bipolar DAC voltage, validating the effectiveness of the mitigation strategy. A three‐stage prototype was constructed, which is capable of delivering up to 180 kV. Laboratory tests on a lumped capacitor and field tests on a 110 kV XLPE cable validated the feasibility and effectiveness of the proposed method. The system maintains the compactness and portability of conventional DAC systems while extending its capability to provide bipolar DAC voltage, thus providing a practical solution for on‐site PD detection of XLPE cables.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Chen et al. (2026) studied this question.

synapsesocial.com/papers/69b3ace502a1e69014ccf016https://doi.org/10.1049/smt2.70051
Ask AI
Helpful
Bookmark
Share
View Full Paper