March 15, 2026The Tohoku Journal of Experimental Medicine0 citationsOpen Access

Evaluation of Optimal Ordered Subset Expectation Maximization Reconstruction for I-123FP-CIT Single-Photon Emission Computed Tomography Using a Ring-Type Semiconductor Scanner

View Full Paper
NYNao YamaguchiTohoku UniversityHOHayato OdagiriTohoku UniversityHSHayato SatoTohoku University

Key Points

  • To evaluate the effectiveness of OSEM reconstruction for I-123 FP-CIT SPECT imaging using a ring-type scanner.
  • Utilized a striatum phantom filled with I-123 solution for imaging experiments.
  • Tested acquisition times of 15, 20, 30, and 120 minutes under various conditions.
  • Reconstructed images using OSEM with varying numbers of updates and Butterworth filters.
  • Compared image quality metrics such as %CV and NMSE between ring-type and conventional scanners.
  • The %CV for the 120 min acquisition was significantly lower when updates reached 100.
  • The NMSE for 20 and 30 min images plateaued after 120 updates.
  • Striatal uptake ratio and contrast ratio were notably superior in the ring-type scanner compared to the Anger-type scanner.
  • Optimal conditions were determined to be 20 min acquisition, 120 OSEM updates, and Butterworth filter cut-offs of 0.4-0.5 cycles/cm.

Abstract

A Recently introduced ring-type single-photon emission computed tomography (SPECT) /computed tomography (CT) scanner equipped with 12 small semiconductor detectors is expected to shorten the acquisition time and improve spatial resolution.This study evaluated the optimal ordered subset expectation maximization (OSEM) reconstruction for I-123 N-omega-fluoropropyl-2beta-carbomethoxy-3beta-(4-iodo-phenyl) nortropane SPECT using a striatum phantom.The phantom was filled with an I-123 solution, and the radioactivity concentration ratio in the background, right striatum, left caudate, and left putamen was 1:8:8:4.The evaluated acquisition time was 15, 20, 30, and 120 min.The acquired data were reconstructed using OSEM under various conditions.The reconstructed images were evaluated regarding coefficient of variation (%CV), normalized mean squared errors (NMSE), and visual interpretation.In addition, the striatal uptake ratio (SUR) and contrast ratio of the images were compared between the ring-type and the conventional 2-detecter (Anger-type) scanner.The %CV of the 120 min image was sufficiently small when the number of updates reached 100 and converged uniformly.The NMSE of the 20 and 30 min images were almost constant when the number of updates exceeded 120.Regarding visual interpretation, cut-off frequencies of 0.4 and 0.5 cycles/cm for the Butterworth filter were considered optimal.The SUR and A c c e p t e d M a n u s c r i p t contrast ratio of the ring-type scanner were significantly higher than those of the Angertype.In conclusion, an acquisition time of 20 min, OSEM reconstruction with 120 updates, and a Butterworth filter of 0.4-0.5 cycles/cm were suitable for I-123 FP-CIT SPECT using a ring-type scanner.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yamaguchi et al. (2026) studied this question.

synapsesocial.com/papers/69b64c33b42794e3e660da04https://doi.org/10.1620/tjem.2026.j005
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Optimization of Block Sequential Regularized Expectation Maximization Reconstruction Parameters for Striatal SPECT Using a Ring-Type Semiconductor SPECT/CT System2025 · 2 citations
  2. 2Comparative Analysis of OSEM Parameters for Cardiac SPECT Imaging Across Multiple Camera Brands: A Monte Carlo Study2024
  3. 3Optimization of acquisition time and reconstruction parameters for quantitative single-photon emission computed tomography/computed tomography using iodine-123 metaiodobenzylguanidine2025
  4. 4Effects of PET image reconstruction parameters and tumor-to-background uptake ratio on quantification of PET images from PET/MRI and PET/CT systems2024 · 1 citations
  5. 5The “Macaroni Sign” of Takayasu’s Arteritis: Figure 1.2009 · 15 citations