March 16, 2026Digital Dentistry Journal0 citationsOpen Access

Continuous real-time pH monitoring with an intraoral sensor wearable: A clinical pilot trial

View Full Paper
APAnina M. PulferESEugenia SettecaseRJRonald E. Jung

Key Points

  • The trial aimed to evaluate the feasibility and clinical applicability of a wireless intraoral pH sensor for continuous monitoring.
  • Conducted a prospective clinical pilot trial
  • Monitored ten participants using a custom-fitted intraoral pH sensor
  • Gathered continuous pH data over two periods of 48 and 14 hours
  • Visualized real-time data on a smartphone during the second period
  • Participants maintained a healthy intraoral pH (>6.6) for approximately 48.4% of the monitoring duration
  • Moderately acidic environments (5.9–6.6) accounted for 35.4% of observation time
  • Highly acidic environments (<5.9) were detected 16.2% of the time
  • Median pH value across both visits was 6.57
  • Daytime acidity was lower (median 6.65) compared to nighttime (median 6.21), with variations linked to diet and rest

Abstract

This prospective clinical pilot trial aims to assess the feasibility and clinical applicability of a wireless intraoral pH sensor appliance for continuous real-time monitoring. Ten participants wore a custom-fitted intraoral pH sensor appliance over two monitoring periods of 48 and 14 hours respectively. Continuous pH data was measured and recorded. In the second measurement period data could be visualized real-time on a smartphone. Participants maintained a healthy intraoral pH (>6.6) for approximately half the monitoring duration (48.4%). A moderately acidic (5.9–6.6) environment was detected for 35.4%, and a highly acidic (<5.9) environment for 16.2% of the observation time. The median pH value across both visits was 6.57 (IQR:1.02). Diurnal variations showed lower daytime (median 6.65, IQR: 1.00) compared to nighttime acidity (median 6.21, IQR: 0.97), with clear pH fluctuations linked to dietary intake and resting periods. The wireless intraoral pH sensor wearable enabled continuous monitoring, providing reliable data on pH variations within the oral cavity over a 48-hour period. The trial serves as a foundational step toward the broader clinical implementation of wearable intraoral pH sensors and real-time monitoring devices and highlights the potential of future diagnostic and therapeutic applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pulfer et al. (2026) studied this question.

synapsesocial.com/papers/69b79e398166e15b153ab47fhttps://doi.org/10.1016/j.ddj.2026.100082
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A new method for continuous in vivo pH measurement in saliva and oral biofilm - a comparative pilot study2025
  2. 2POC device for rapid oral pH determination based on a smartphone platform2024 · 5 citations
  3. 3Smart Oral Guard: Continuous Heart Health Monitoring Using Salivary Biomarkers And Photoplethysmography2026
  4. 4Use of Biosensors within the Oral Environment for Systemic Health Monitoring—A Systematic Review2024 · 2 citations
  5. 5Bioresorbable, wireless, passive sensors for continuous pH measurements and early detection of gastric leakage2024 · 70 citations