March 18, 2026Journal of Manufacturing and Materials Processing0 citationsOpen Access

Dental Model Analysis in Orthognathic Surgery: Accuracy of 3D Printed FDM and SLA Models in Comparison to Original STL File: An In Vitro Analysis

View Full Paper
TBThijs BauwensPCPasquier CorthoutsLKLisa De Kock

Key Points

  • The study aims to evaluate the dimensional accuracy of dental models produced by FDM and SLA printing methods compared to the original STL files.
  • Utilized STL files from intraoral scans of 20 patients to create 40 dental models.
  • Fabricated models using both FDM and SLA printing techniques.
  • Aligned models with reference STL files for analysis of dimensional deviations.
  • SLA models showed significantly higher dimensional accuracy than FDM models, with deviations of 1.42 mm vs. 1.84 mm.
  • Both techniques achieved clinically acceptable accuracy for splint fitting, with mean deviations below 0.05 mm.
  • FDM models exhibited higher median deviation compared to SLA models (0.0267 mm vs. 0.00145 mm).

Abstract

3D printing is an important part of orthognathic surgery by enabling accurate anatomical models for preoperative planning. While Stereolithography (SLA) is widely regarded as the gold standard due to its high precision, recent improvements in Fused Deposition Modeling (FDM) raise the question whether PLA-based dental models can provide comparable dimensional accuracy at a lower cost. This study compares FDM and SLA dental models to evaluate whether FDM represents a clinically viable alternative. STL files derived from maxillary and mandibular intraoral scans (IOS) of 20 patients, yielding 40 dental models, were fabricated using both printing techniques. All models were aligned to the reference STL files and analyzed for dimensional deviations. SLA models demonstrated significantly higher dimensional accuracy than PLA-based FDM models, with lower maximum deviations from the reference STL (1.42 mm vs. 1.84 mm). Both techniques achieved clinically acceptable accuracy for splint fitting, with mean deviations below 0.05 mm. Regarding internal validity, both printers showed high reproducibility, although FDM models exhibited a higher median deviation compared to SLA models (0.0267 mm vs. 0.00145 mm). While SLA remains preferable for high-precision indications, FDM offers a cost-effective alternative for routine clinical use without compromising clinical applicability.