The Potential Role of an Artificial Intelligence-Driven Tool in Decision-Making for Mitral Valve Repair Surgery

View Full Paper
SASerdar AkanselMDMartina DiniSSSimon Sündermann

Key Result

A fully automated, CT-based artificial intelligence tool accurately predicted annuloplasty ring size in 78.8% of patients undergoing minimally invasive mitral valve repair.

Key Points

  • To evaluate the predictive capability of an AI-driven tool for annuloplasty ring sizing in mitral valve repair surgeries.
  • Analyzed preoperative CT scans from 71 patients undergoing minimally invasive MV repair.
  • Used a cloud-based AI tool to quantify mitral valve geometric parameters.
  • Assessed correlations between AI-derived measurements and implanted ring sizes using Pearson correlation.
  • Performed univariable and multivariable linear regression analyses to identify predictors of ring size selection.
  • Significant correlations between AI-derived parameters and implanted ring sizes were found.
  • Strongest correlations noted for commissural width and mitral annular area (R = 0.693, p < 0.001).
  • The model predicted accurate annuloplasty ring sizing in 78.8% of patients.
  • No in-hospital mortality or residual mitral regurgitation at discharge.

Structured PICO

Does a fully automated CT-based AI tool accurately predict annuloplasty ring size in patients undergoing minimally invasive mitral valve repair?

P
Population
Patients undergoing minimally invasive mitral valve repair (MI-MVr) for Carpentier type II mitral valve insufficiency
I
Intervention
Preoperative CT scan analysis using a cloud-based, fully automated AI-driven tool to quantify mitral valve geometric parameters
O
Outcome
Predictive capability/accuracy of the AI tool for annuloplasty ring sizingsurrogate

A fully automated CT-based AI tool can accurately predict annuloplasty ring size in nearly 80% of patients undergoing minimally invasive mitral valve repair, potentially improving surgical planning and reproducibility.

Abstract

Background: Annuloplasty ring sizing is critical for durable outcomes in surgical mitral valve repair (MVr). However, there is no clear consensus on optimal sizing strategies. Artificial intelligence (AI)-based imaging tools may help to reduce uncertainty in preoperative decision-making by providing objective, reproducible and reliable measurements. This study evaluated the predictive capability of a fully automated, computed tomography (CT)-based AI-driven tool for annuloplasty ring sizing in patients undergoing minimally invasive MVr (MI-MVr). Methods: A total of 71 consecutive patients undergoing MI-MVr for Carpentier type II mitral valve insufficiency during the study period were included. Preoperative CT scans were analyzed using a cloud-based, fully automated AI tool to quantify mitral valve geometric parameters. Correlations between AI-derived measurements and implanted ring sizes were assessed using the Pearson correlation test. Univariable and multivariable linear regression analyses were performed to identify independent predictors of ring size selection. Results: Several AI-derived parameters correlated significantly with implanted ring size, with the strongest correlations observed for commissural width (R = 0.693, p < 0.001) and mitral annular area (R = 0.693, p < 0.001). In multivariable regression analysis, these parameters were the strongest predictors of annuloplasty ring size (R2 = 0.504, p < 0.001). Using this model, accurate annuloplasty ring sizing could be predicted in 78.8% of patients. There were no in-hospital mortality and residual mitral regurgitation at discharge. Conclusions: A fully automated, CT-based AI-driven tool demonstrated good accuracy for preoperative annuloplasty ring size prediction in MI-MVr and may have the potential to support surgical decision-making, reduce operator dependence, and improve reproducibility.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Akansel et al. (2026) studied this question. A fully automated, CT-based artificial intelligence tool accurately predicted annuloplasty ring size in 78.8% of patients undergoing minimally invasive mitral valve repair.