PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 19, 2026Respiration0 citations

Value of Endobronchial Ultrasound-Derived Radiomics in Differentiating Pulmonary Sarcoidosis from Mediastinal Lymph Node Tuberculosis

View Full Paper
QZQuncheng ZhangMZMengyu ZhaoFWFeifei Wen

Key Points

  • This research aims to evaluate the effectiveness of an ultrasound radiomics model in distinguishing between pulmonary sarcoidosis and mediastinal lymph node tuberculosis.
  • Collected clinical data and ultrasound images from 100 sarcoidosis patients and 70 tuberculosis patients.
  • Analyzed clinical features such as age, gender, and lymph node size.
  • Used Lasso for feature selection and support vector machine for model establishment.
  • Divided lymph nodes into training (119 nodes) and validation groups (51 nodes) for performance assessment.
  • Identified seven significant radiomics features and four clinical features for the model.
  • The SVM model achieved a ROC AUC of 0.909 in training and 0.917 in validation groups.
  • Achieved 88.2% accuracy, 82.4% sensitivity, and 92.6% specificity in training and 80.4% accuracy, 68.4% sensitivity, and 87.5% specificity in validation.

Abstract

Introduction: To explore the feasibility of an ultrasound radiomics machine learning model based on endobronchial ultrasound (EBUS) for differentiating pulmonary sarcoidosis from mediastinal lymph node tuberculosis. Methods: Clinical characteristics and ultrasound image data from 100 patients diagnosed with pulmonary sarcoidosis and 70 patients diagnosed with mediastinal lymph node tuberculosis were collected. Statistical analysis was performed to compare clinical features, such as age, gender, smoking history, and lymph node size and so on, between the two groups. The least absolute shrinkage and selection operator (Lasso) was used to analyze the radiomics features extracted from EBUS-based ultrasound images. A support vector machine (SVM) algorithm was applied to establish an EBUS-based radiomics model, and clinical features with statistically significant were incorporated to optimize the model. A total of 170 lymph nodes were randomly divided into training group (n=119) and validation group (n=51), with the diagnostic performance of the model assessed using receiver operating characteristic (ROC) curves and the area under the curve (AUC), accuracy, sensitivity, and specificity. Results: Seven stable radiomics features with non-zero coefficients and four clinical features were selected as inputs for the model. The SVM model demonstrated great performance in both groups. In the training group, the ROC AUC of the SVM model was 0.909 (95% CI: 0.897-0.922), with an accuracy of 88.2%, sensitivity of 82.4%, and specificity of 92.6%. In the validation group, the ROC AUC was 0.917 (95% CI: 0.901-0.934), with an accuracy of 80.4%, sensitivity of 68.4%, and specificity of 87.5%. Conclusion: The SVM model based on EBUS ultrasound radiomics and clinical data shows promising feasibility for differentiating pulmonary sarcoidosis from mediastinal lymph node tuberculosis. It exhibits significant potential in clinical practice and provides a new method for the early diagnosis of these conditions.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zhang et al. (2026) studied this question.

synapsesocial.com/papers/69bb9313496e729e62980daehttps://doi.org/10.1159/000551556
Ask AI
Helpful
Bookmark
Share
View Full Paper