PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 21, 2026Biomedical Chromatography0 citationsOpen Access

Analytical Quality by Design‐Guided Optimisation and Validation of a Short‐Run Stability‐Indicating Reverse‐Phase Ultra‐Fast Liquid Chromatography (RP‐UFLC) Method for the Quantitation of Nonivamide

View Full Paper
PMPhindile MahlanguMPMadan PokaPMPedzisai A. Makoni

Key Points

  • The aim is to develop and validate a reverse-phase liquid chromatography method for accurate quantification of nonivamide.
  • Developed a RP-HPLC method using response surface methodology.
  • Validated according to ICH guidelines for linearity, LOD, LOQ, precision, and accuracy.
  • Evaluated method greenness with AGREE scoring system.
  • Performed stress studies to assess nonivamide stability under various conditions.
  • Optimised conditions achieved NON elution at 6.8 minutes with a resolution of 13.
  • %RSD was below 5%, confirming method robustness.
  • Linear range was established at 2-200 μg/mL, with LOD at 0.67 μg/mL and LOQ at 2 μg/mL.
  • Stability studies showed NON remained stable under most conditions except alkaline and oxidative stress.

Abstract

Nonivamide (NON), a capsaicin analogue with similar pharmacological effects, is used in pain management, yet limited information exists on its accurate quantification by reverse-phase liquid chromatography. A cost-effective, efficient and precise RP-HPLC method was developed, optimised using response surface methodology (central composite design), validated and assessed for greenness. Naproxen served as the internal standard. Acetonitrile (ACN) with a potassium phosphate buffer achieved separation, with detection at 285 nm. Critical analytical attributes included retention times, resolution and solvent composition. Optimised conditions were 41.0% v/v of ACN, a flow rate of 1.5 mL/min and a buffer of pH 4. Under these conditions, NON eluted at 6.8 min with a resolution of 13 and %RSD < 5%, aligning with model predictions, confirming robustness and system suitability. Greenness evaluation (AGREE) yielded a score of 0.72 (good-very good). Method validation followed the ICH guidelines: linearity of 2-200 μg/mL, LOD of 0.67 μg/mL and LOQ of 2 μg/mL. Precision and accuracy were within acceptable limits (< 5%). Stress studies revealed NON stability under most conditions, except alkaline and oxidative stress, whereas specificity was confirmed by detection in the presence of degradants. Overall, the developed method is robust, reproducible, reliable and environmentally considerate, enabling accurate NON quantification from pharmaceutical bulk.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Mahlangu et al. (2026) studied this question.

synapsesocial.com/papers/69be36bf6e48c4981c675df3https://doi.org/10.1002/bmc.70423
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Improving Pharmacy Students' Understanding and Long-term Retention of Acid-Base Chemistry2007 · 14 citations
  2. 2Analytical Eco-Scale for assessing the greenness of analytical procedures2012 · 2,452 citations
  3. 3Engineering a biomimicking strategy for discovering nonivamide-based quorum-sensing inhibitors for controlling bacterial infection2024 · 26 citations
  4. 4ANN modelling of fractal dimension in machining2012 · 50 citations
  5. 5Development of forced degradation and stability indicating studies of drugs—A review2013 · 1,031 citations