March 24, 2026European Respiratory Journal0 citations

Bronchoscopy in chronic respiratory failure using Boussignac system with CO 2 new device

View Full Paper
OGOsvaldo Della GattaCGCarmine GuarinoDTDomenico Turco

Key Points

  • To evaluate the efficacy and safety of the Boussignac CPAP system with EtCO2 device during bronchoscopy in chronic respiratory failure.
  • Involved 38 patients undergoing bronchoscopy with topical anesthesia.
  • Utilized Boussignac CPAP system with an EtCO2 device via facemask.
  • Monitored oximetry, heart rate, and EtCO2 levels throughout the procedure.
  • Bronchoscopy was successfully completed in all patients without complications.
  • Achieved O2 saturations > 94% and PaO2/FiO2 > 350 in the majority of procedures.
  • Conducted 10 TBNA, 9 biopsies, and 5 bronchial aspirations, highlighting the effectiveness in COPD patients.

Abstract

Introduction The diagnostic bronchoscopy, in chronic hypoxemic patients with normo/hypo/hypercapnia is not always feasible, although the standard oxygen delivery, for the clinical severity or comorbidity, was possible by Continuous Positive Airway Pressure (CPAP) system with bite block of end tidal CO 2 (EtCO 2 ) new device. Objectives We employed the Boussignac CPAP (B-CPAP) system with EtCO 2 device, in the chronic respiratory failure, to cope further hypoxemia related with the procedure itself and especially in the bronchoalveolar lavage (BAL) and in the biopsy techniques. Methods 38 patients, in topical anesthesia, spontaneously breathing (23 men, 15 women, median age 64,58 years, partial pressure for oxygen/fraction of inspired oxygen PaO 2 /FiO 2 238-280, pCO 2 28-53 mmHg) received B-CPAP system applied to a facemask, monitoring oximetry, heart rate, EtCO 2 through a special mouthpiece. Results In our study, the bronchoscopy has been completed in all patients without subsequent complications with application of B-CPAP system through a bite block of EtCO 2 device. 10 TBNA, 9 biopsies, 5 bronchial aspirations in COPD were made with saturations in O 2 94%, PaO 2 /FiO 2 350 also in 14 BAL, that cause desaturation with a significant hypoxemia. Moreover, in a patient with EtCO 2 of 53mmHg, the bronchoscopy, limited to a fast airway inspection with aspiration, did not give complications, even with a moderate CO 2 increase. Conclusions B-CPAP system, during bronchoscopic maneuvers, for oximetry, EtCO 2 , for the reduction of dyspnea, formed, in our experience, an alternative procedure to the endotracheal intubation and mechanical ventilation, expecially in COPD patients with tendency toward hypercapnia.