March 25, 2026Sensors3 citationsOpen Access

Electrochemical Biosensing Platforms for Rapid and Early Diagnosis of Crop Fungal and Viral Diseases

View Full Paper
YZYuhong ZhengJilin Academy of Agricultural SciencesLFLi FuChinese Academy of Tropical Agricultural SciencesJYJiale YangInstitute of Botany

Key Points

  • Evaluate advances in electrochemical biosensing for early detection of fungal and viral crop diseases.
  • Focused on immunosensors, genosensors, aptasensors, and VOC-based systems.
  • Analyzed detection limits, response times, and performance metrics.
  • Discussed limitations and innovations in bio-sensing technologies.
  • Achieved ultralow detection limits for pathogens, including 0.3 fg mL−1 for viral proteins.
  • Genosensors and aptasensors demonstrated the lowest limits of detection (LODs) due to amplification methods.
  • Despite strong lab results, challenges in real-world applications include electrochemical interference and environmental factors.

Abstract

Crop fungal and viral diseases cause annual economic losses exceeding USD 150 billion globally, demanding rapid, sensitive, and field-deployable diagnostic technologies. This review critically evaluates recent advances in electrochemical biosensing platforms for early crop pathogen detection, focusing on immunosensors, genosensors, aptasensors, and VOC-based systems. Reported analytical performances demonstrate ultralow detection capabilities, including 0.3 fg mL−1 for viral coat proteins, 15 DNA copies for bacterial pathogens, 0.5 fg µL−1 RNA detection for viroids, and nanomolar-level VOC sensing (35–62 nM), with response times ranging from 2 to 60 min. Comparative analysis reveals that genosensors and aptasensors generally achieve the lowest LODs due to nucleic acid amplification or high-affinity recognition, while immunosensors provide robust protein-level specificity validated against ELISA. Volatile organic compound (VOC) sensors enable non-invasive, pre-symptomatic monitoring but face specificity challenges. Despite strong laboratory performance, practical adoption is limited by matrix-derived electrochemical interference, environmental instability of biorecognition elements, workflow complexity, and insufficient standardization across studies. Emerging innovations, including magnetic bead enrichment, nanoporous and graphene-based electrodes, microfluidic integration, AI-assisted impedance interpretation, and biodegradable substrates, are progressively addressing these bottlenecks. This review emphasizes that successful field translation requires holistic workflow engineering, matrix-matched validation, and harmonized performance metrics rather than incremental sensitivity improvements alone. By integrating analytical chemistry, nanomaterials engineering, and agricultural decision-support frameworks, electrochemical biosensing platforms hold significant potential to enable decentralized, rapid, and sustainable crop disease management.