March 25, 2026Advanced Energy Materials0 citationsOpen Access

Selective Electrolysis of Water Under Artificial Seawater Conditions Using Transition Metal Borate Anodes

View Full Paper
AFAnanta R. FarezaHGHank GargLALuis Miguel Azofra

Key Points

  • The aim is to enable hydrogen production from seawater by overcoming the limitations of conventional electrolyzers.
  • Developed an electrolyzer using artificial seawater without added electrolytes.
  • Utilized cobalt iron boride anodes to favor oxygen evolution.
  • Conducted operation tests at 80 ± 1°C with a current density of 100 mA cm −2.
  • Achieved selective splitting of H 2 O instead of H 2 generation with CER.
  • Robust operation maintained for one week.
  • Demonstrated functioning at cell voltage of approximately –2.6 V.

Abstract

ABSTRACT Direct seawater electrolysis overcomes one major hurdle in sustainable hydrogen production, viz. the requirement to use high‐purity water, which is currently a scarce resource for ∼80% of the global population. On the other hand, the natural composition of seawater makes it unsuitable for direct use in conventional electrolyzer systems, primarily due to the occurrence of the chlorine evolution reaction (CER) at the anode, instead of the desired oxygen evolution reaction (OER), and the build‐up of insulating Mg 2+ /Ca 2+ hydroxides at the cathode. Herein, we present an electrolyzer fed with artificial seawater with no added electrolyte and enabling selective splitting of H 2 O, rather than H 2 generation coupled to the CER. This selectivity was provided by the anodes derived from a cobalt iron boride material, which was predicted to favor the OER rather than the CER by the density functional theory calculations. The compact design of the electrode‐separator assembly suppressed the cathodic Mg/Ca(OH) 2 precipitation. Robust operation of the electrolyzer over one week was demonstrated at 100 mA cm −2 with a cell voltage of ca. –2.6 V at 80 ± 1°C. These operating conditions were selected based on a preliminary techno‐economic analysis as a realistic benchmark for cost‐competitive hydrogen production.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fareza et al. (2026) studied this question.

synapsesocial.com/papers/69c37c33b34aaaeb1a67efbbhttps://doi.org/10.1002/aenm.202506788