PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 26, 2026ACS Omega0 citationsOpen Access

A Chimeric LBT-GFP Biosensor Exhibits Antithetical Fluorescence Responses to Ca 2+ and Dy 3+ Binding

View Full Paper
JLJu LiSOSandra OloketuyiLHLi-Wei Hung

Key Points

  • The aim is to design and characterize a biosensor that selectively responds to lanthanides and calcium ions.
  • Design of a genetically encoded fluorescence indicator combining sfGFP with a dual lanthanide-binding tag.
  • Characterization of fluorescence intensity responses to different concentrations of lanthanides and calcium.
  • Assessment of the dynamic range of fluorescence changes under varying metal ion concentrations.
  • The biosensor showed distinct fluorescence changes in response to dysprosium and other lanthanides.
  • Low concentrations of lanthanides initially quenched fluorescence, while higher concentrations increased it by 1.5-fold.
  • Pre-treating the sensor with calcium increased the dynamic range of fluorescence response to dysprosium up to 3-fold.

Abstract

Rare earth elements (REEs) are critical components in emerging technologies, but their mining and refining processes are often laborious, costly, and environmentally damaging. Developing green and efficient separation methods for REEs is crucial. Biomolecular approaches using lanthanide-binding proteins and peptides show promise for selective REE extraction and separation. In this study, we present the design and characterization of a genetically encoded fluorescence indicator (GEFI) construct that combines a superfolder green fluorescent protein (sfGFP) with a dual lanthanide-binding tag (2×dLBT). The 2×dLBT insert induces conformational changes in sfGFP upon lanthanide binding, modulating the fluorescence intensity. The sfGFP-2×dLBT biosensor exhibited distinct fluorescence responses to different lanthanide ions, with the highest dynamic range observed for heavy REEs like dysprosium (Dy3+). Interestingly, the sensor displayed an antithetical response, where low concentrations of lanthanides initially quenched the fluorescence, but higher concentrations led to a significant fluorescence increase (1.5-fold). The Ca2+ ion on the other hand showed only a dose-dependent quenching of the fluorescence response. Based on these observations, the biphasic response of the biosensor to lanthanides was eliminated by pretreating the sensor with calcium, which further expanded the dynamic range up to 3-fold for Dy3+. The lanthanide-selective and concentration-dependent fluorescence changes of the sfGFP-2×dLBT biosensor demonstrate its potential as a platform for developing specific sensors for various REEs. These sensors could enable rapid and cost-effective determination of REE composition in complex mixtures, facilitating the separation and recovery of critical REEs from electronic waste and other REE-containing sources.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Li et al. (2026) studied this question.

synapsesocial.com/papers/69c4ccebfdc3bde4489189d1https://doi.org/10.1021/acsomega.5c10135
Ask AI
Helpful
Bookmark
Share
View Full Paper