PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 26, 2026Journal of Functional Biomaterials0 citationsOpen Access

Sterilization-Induced Property Changes in FDM-Printed Carbon Fiber-Reinforced Polycarbonate for Medical Device Applications

View Full Paper
ARAbel RemacheWPWilson PavónUniversidad UTEOVOscar Jara Vinueza

Key Points

  • This study aims to explore how different sterilization methods affect the properties of carbon fiber-reinforced polycarbonate used in 3D printing.
  • Analyzed mechanical properties through tensile, impact, and hardness tests
  • Conducted thermomechanical analysis (TMA) and dynamic mechanical analysis (DMA)
  • Compared effects of ethylene oxide and hydrogen peroxide vapor sterilization methods
  • EO sterilization reduced elongation at break by approximately 20% and lowered glass transition temperature
  • HP-treated samples showed a 16% reduction in stiffness (Young modulus) with increased Tg
  • Distinct viscoelastic behaviors observed between the two sterilization methods

Abstract

Fused deposition modeling (FDM) of carbon fiber-reinforced polycarbonate (PC-CF) is increasingly used in medical applications due to its excellent strength-to-weight ratio and adaptability for custom geometries. However, sterilization is a critical step that may compromise the structural integrity of polymer composites. This study investigates the effects of two low-temperature sterilization methods—ethylene oxide (EO) and hydrogen peroxide vapor (HP)—on the mechanical, thermal, and viscoelastic properties of FDM-printed PC-CF parts. Characterization included tensile, impact, and hardness tests; thermomechanical analysis (TMA); and dynamic mechanical analysis (DMA). EO sterilization resulted in approximately 20% reduced elongation at break and lower glass transition temperature, indicating a loss of ductility and thermal stability. HP-treated samples showed reduced stiffness (16% in Young modulus) but increased Tg and reduced thermal expansion, suggesting improved dimensional stability. DMA results confirmed distinct viscoelastic behavior between treatment types. These findings provide evidence for selecting appropriate sterilization protocols for FDM-manufactured PC-CF components used in functional medical devices.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Remache et al. (2026) studied this question.

synapsesocial.com/papers/69c4cda5fdc3bde44891a43ahttps://doi.org/10.3390/jfb17040159
Ask AI
Helpful
Bookmark
Share
View Full Paper