PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 26, 2026General Thoracic and Cardiovascular Surgery0 citationsOpen Access

PANORAMITRA: a novel polyetheretherketone-based perivalvular tissue retractor for use in minimally invasive and conventional cardiac surgery

YIYusuke InabaHKHiroshi Kubota

Key Result

The PANORAMITRA perivalvular tissue retractor was successfully applied in approximately 20 cardiac surgery cases without structural failure, providing consistent subvalvular exposure.

Key Points

  • To describe the clinical application of PANORAMITRA, a new retractor, in mitral valve surgery.
  • Developed a novel perivalvular retractor using medical-grade polyetheretherketone (PEEK).
  • Deployed the device through a mini-thoracotomy.
  • Positioned the retractor to enhance visualization of subvalvular structures.
  • Improved exposure of subvalvular tissues, particularly papillary muscles.
  • Facilitated mitral valve repair techniques in challenging cases.
  • Provided a practical solution for surgeries involving redundant leaflet tissue.

Structured PICO

P
Population
Patients undergoing minimally invasive and conventional cardiac surgery, particularly degenerative mitral valve surgery
I
Intervention
PANORAMITRA perivalvular tissue retractor (made of medical-grade polyetheretherketone)
O
Outcome
Subvalvular visualization and device durability/safety

The novel PANORAMITRA retractor provides a practical, reusable, and stable solution for achieving consistent subvalvular exposure during minimally invasive and conventional mitral valve surgery.

Limitations

  • Surface scratches caused by surgical instruments were observed after repeated use.
  • Device lifespan is limited to approximately ten clinical uses to maintain safety and performance.
  • Small number of clinical cases reported.
  • Surface scratches caused by surgical instruments were observed after repeated use, necessitating disposal after approximately ten clinical uses

Abstract

In degenerative mitral valve surgery, repair typically involves annuloplasty, resection ofdiseased segments, and neochordal implantation for leaflet resuspension. However,subvalvular exposure, particularly of the papillary muscles, remains technicallychallenging under minimally invasive approaches—especially in patients withredundant leaflet tissue. Here, we describe the clinical application of “PANORAMITRA,” (Senko MedicalInstrument Mfg. Co., Ltd., Tokyo, Japan) a novel perivalvular retractor originally designed and developed by our surgical team, made of medical-gradepolyetheretherketone (PEEK). The device can be easily deployed through a mini-thoracotomy and precisely positioned within the mitral annulus to facilitate subvalvular visualization. Key words

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Inaba et al. (2026) studied Cardiac surgery requiring subvalvular exposure (n=20). PANORAMITRA perivalvular tissue retractor was evaluated on Structural failure during clinical use. The PANORAMITRA perivalvular tissue retractor was successfully applied in approximately 20 cardiac surgery cases without structural failure, providing consistent subvalvular exposure.

synapsesocial.com/papers/69c4cdb6fdc3bde44891a702https://doi.org/10.1007/s11748-026-02284-w