PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 28, 2026Journal of Radiotherapy in Practice0 citationsOpen Access

Qualitative and quantitative evaluation of auto-segmented clinical target volumes and organs at risk in radiotherapy of rectal cancer

LDLove Dahlstedt-HasslerASAlbert SiegbahnRKRafat Kojoj

Key Points

  • This study assesses the quality of auto-segmented clinical target volumes and organs at risk in rectal cancer radiotherapy compared to manual contouring.
  • Collected dose-planning data from 10 patients undergoing preoperative radiotherapy in 2024.
  • Compared auto-segmented structures generated by AI-Rad and Contour+ to manually contoured volumes using quantitative metrics.
  • Evaluated both constructed AI-CTVs and MC-CTVs qualitatively by two radiotherapists.
  • Median volumetric Dice similarity coefficient for AI-CTVs compared to MC-CTVs was 0.86, indicating good similarity.
  • Qualitative assessments favored manual contouring over auto-segmented CTVs.
  • Auto-segmentation quality varied, with poorer coverage in specific anatomical areas.

Abstract

Abstract Introduction: Manual contouring (MC) is time-consuming work in radiotherapy planning for rectal cancer. Artificial intelligence (AI) can reduce the time required for clinical target volume (CTV) and organs-at-risk (OARs) delineation. In this study, we evaluated the quality of auto-segmented CTVs and OARs. Methods: Dose-planning data were collected from ten patients who underwent preoperative radiotherapy for locally advanced rectal cancer in 2024. Auto-segmented structures from the AI-Rad and Contour+ software tools were added. Constructed AI-CTVs, based on Contour+ segmentations and AI-OARs, i.e., bladder, femoral heads and bowel bag, by both AI tools, were compared to their MC counterparts by use of quantitative metrics, volumetric/surface Dice similarity coefficients (vDSC/sDSC) and maximum/average Hausdorff distance (HD/aHD). The constructed AI-CTVs and MC counterparts were graded by two radiotherapists with two qualitative methods. Results: The median vDSC, sDSC, HD and aHD values of our constructed AI-CTVs compared with the MC-CTVs were 0.86, 0.61, 23.19 and 0.62 mm, respectively. For both AI tools, the agreement in the OAR metrics was overall good but less similar for the bowel bag. The qualitative evaluations of the AI-CTVs, compared to the MC-CTVs, were in clear favour of the MC-CTVs. The cranial-anterior nodal levels were anatomical areas with poorer coverage, where the contouring guidelines differed. Conclusion: The quality of our constructed AI-CTVs was inferior to the MC-CTVs. Thus, the auto-segmentation methods need further development on this aspect for use in the clinical setting. In contrast, the agreement of the quantitative metrics for the OARs was overall good, except for the bowel bag.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dahlstedt-Hassler et al. (2026) studied this question.

synapsesocial.com/papers/69c772158bbfbc51511e24d9https://doi.org/10.1017/s1460396926100405
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Localized fine-tuning and clinical evaluation of deep-learning based auto-segmentation (DLAS) model for clinical target volume (CTV) and organs-at-risk (OAR) in rectal cancer radiotherapy2024 · 4 citations
  2. 2Review of Deep Learning Based Autosegmentation for Clinical Target Volume: Current Status and Future Directions2024 · 37 citations
  3. 3Errors and margins in radiotherapy2004 · 1,413 citations
  4. 4Uncertainties in target volume delineation in radiotherapy – are they relevant and what can we do about them?2016 · 143 citations
  5. 5Incidence trends and long-term survival in early-onset colorectal cancer: a nationwide Swedish study2025 · 19 citations