March 29, 2026Bulletin of Earthquake Engineering0 citationsOpen Access

Partial safety factor for seismic design of isolation systems consistent with second-generation Eurocode 8

PFPaolo FranchinMFMarco FuringhettiFNFabrizio Noto

Key Points

  • This study aims to develop a partial safety factor for the displacement capacity of seismic isolators to enhance structural reliability.
  • Derived values to achieve Near Collapse reliability targets per second-generation Eurocode 8.
  • Conducted numerical assessments using multiple-stripe inelastic response history analyses.
  • Considered damage in isolators and super-structure to evaluate safety factor reduction.
  • Identified reduced partial safety factor values that correspond with controlled damage in isolators.
  • Demonstrated that seismic isolation can offer better performance under low-intensity seismic events while reducing safety margins for higher intensities.

Abstract

A seismically isolated structure comprises the isolation system, the substructure and the superstructure. The design of the former is displacement-based, i.e., demand and capacity of the devices are in terms of displacement, subject to force constraints such as the transmission of vertical loads. Design of the latter is traditionally force-based, i.e., based on strength verifications of members. Design of the substructure is in between, with the sizing of the rattle-space being displacement-based and that of connection elements being force-based. International codes adopt different safety margins in the design of each of these three components. Sometimes, this leads to structures that, even though performing better than their fixed-base counterparts at lower intensities up to the design one, have a lower safety margin with respect to collapse. This paper focuses on the partial safety factor to be adopted in the design of the isolators’ displacement capacity. Values are derived to meet the Near Collapse reliability target set in the code, employing the same theoretical framework used to derive partial factors for displacement-based design of structural members in fixed-base structures, for the second-generation Eurocode 8. Even though seismic isolation can provide better-than-code performance, admitting some degree of damage allows relaxing design requirements to just match the regular code performance objective. Numerical assessment via multiple-stripe inelastic response history analyses, capable of considering the full range of phenomena occurring at higher than design seismic intensities, including device and super-structure damage, is thus used to show how the partial safety factor value can be reduced as a function of admissible (controlled) damage in the isolators.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Franchin et al. (2026) studied this question.

synapsesocial.com/papers/69c8c195de0f0f753b39bedahttps://doi.org/10.1007/s10518-026-02437-5
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Investigating the impacts of design ductility values and importance levels on the performance of base-isolated buildings in New Zealand2025 · 2 citations
  2. 2Drivers to seismic hazard curve slope2024 · 7 citations
  3. 3Seismic Isolation for Architects2016 · 15 citations
  4. 4Engineering seismic risk analysis1968 · 3,803 citations
  5. 5Design of Seismic Isolated Structures1999 · 1,183 citations