April 1, 2026European Heart Journal Supplements0 citations

Comprehensive assessment of 1-year echocardiograms after transcatheter aortic valve implantation: insights from the LANDMARK trial

View Full Paper
ATA TobeYOY OnumaNRN Van Royen

Key Result

The Myval THV demonstrated a mean effective orifice area of 2.12 cm2 at 1 year, larger than the Sapien THV (1.95 cm2, p=0.002) but smaller than the Evolut THV (2.25 cm2, p=0.01).

Key Points

  • To assess the echocardiographic performance of Myval vs. contemporary transcatheter heart valves one year post-implantation.
  • Multicentre randomized trial design with 768 patients
  • Randomization to Myval or contemporary THV groups
  • Follow-up echocardiograms analyzed at an independent core laboratory
  • Echocardiographic parameters assessed include effective orifice area (EOA)
  • Analysis stratified by valve size, aortic annulus area, sex, and stroke volume index (SVi)
  • One-year echocardiographic data obtained for 629 patients
  • Mean EOA was higher for Myval than Sapien, but lower than Evolut
  • Significant differences in EOA observed based on aortic annulus size and sex
  • Patients with low flow status had smaller EOA compared to those with normal or high flow

Study Design

Type

RCT (n=768)

Randomization

1:1

Multicenter

Yes

Structured PICO

Does the Myval transcatheter heart valve provide a different 1-year effective orifice area compared to Sapien and Evolut valves in patients with symptomatic severe aortic stenosis?

P
Population
629 patients with symptomatic severe aortic stenosis (from a total randomized cohort of 768) with available 1-year echocardiographic data
I
Intervention
Myval balloon-expandable transcatheter heart valve
C
Comparator
Contemporary transcatheter heart valves (Sapien or Evolut series)
O
Outcome
Effective orifice area (EOA) at 1 year assessed by an independent core laboratorysurrogate

At 1 year post-TAVI, the Myval balloon-expandable valve demonstrated a larger effective orifice area than the Sapien valve but a smaller area than the Evolut valve.

Main Result

p-value: p=0.002 vs Sapien; p=0.01 vs Evolut

Abstract

Abstract Background In the LANDMARK trial, the Myval balloon-expandable balloon transcatheter heart valve (THV) series demonstrated non-inferiority compared with the two most commonly used contemporary THVs – Sapien and Evolut series – at 30 days and 1 year. Purpose This substudy reports the detailed echocardiographic assessment at 1 year. Methods The LANDMARK trial is a multicentre randomized trial comparing the performance of the Myval THV series with the contemporary THV series. A total of 768 patients with symptomatic severe aortic stenosis were randomized to either the Myval or contemporary group. Patients in the contemporary group were further randomized 1:1 to receive a Sapien or Evolut series. One-year echocardiograms were analysed at an independent core laboratory. Echocardiographic parameters, including effective orifice area (EOA), were stratified according to implanted valve size, computed tomography-based preprocedural aortic annulus area, sex, and stroke volume index (SVi). Analyses were performed in the as-treated population. Results One-year echocardiographic data with available EOA were obtained in 629 patients (Myval 304, Sapien 164, and Evolut 161). Mean EOA was 2.12±0.55, 1.95±1.84, and 2.25±2.20 cm2 for Myval, Sapien and Evolut, respectively (Myval vs Sapien, p=0.002; Myval vs Evolut, p=0.01). Myval and Sapien showed a stepwise increase in EOA according to valve size (Figure 1). In patients with small annulus (≦430 mm2), EOA was 1.82±0.48, 1.64±0.50, and 2.18±0.50 cm2, respectively (Myval vs Sapien, p=0.03; Myval vs Evolut, p0.0001). When aortic annulus area was further divided into four categories based on the manufacturer’s recommended ranges for Sapien valve sizes (273-345, 338-430, 430-546, 540-680 mm2), similar results were observed. In female patients, EOA was 1.96±0.54, 1.69±0.45, and 2.25±0.49 cm2 (Myval vs Sapien, p=0.0001; Myval vs Evolut, p0.0001). Across all valve types, patients with low flow status (SVi35 ml/m2) had smaller EOA compared with those with normal flow (SVi 35-50 ml/m2), whereas those with high flow (SVi50) had larger EOA. Whitin each flow category, Myval demonstrated larger EOA than Sapien but smaller than Evolut. Conclusions A comprehensive assessment of 1-year echocardiographic data was performed. Irrespective of stratification, Myval had higher EOA than Sapien where as small EOA than Evolut.EOA per valve type and sizeFor image description, please refer to the figure legend and surrounding text. EOA stratified by aortic annulus areaFor image description, please refer to the figure legend and surrounding text.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tobe et al. (2026) conducted an RCT in symptomatic severe aortic stenosis (n=768). Myval THV series vs. Sapien or Evolut THV series was evaluated on Mean effective orifice area (EOA) at 1 year (p=p=0.002 vs Sapien; p=0.01 vs Evolut). The Myval THV demonstrated a mean effective orifice area of 2.12 cm2 at 1 year, larger than the Sapien THV (1.95 cm2, p=0.002) but smaller than the Evolut THV (2.25 cm2, p=0.01).

synapsesocial.com/papers/69ccb74216edfba7beb891c3https://doi.org/10.1093/eurheartjsupp/suag056.072
Ask AI
Helpful
Bookmark
Share
View Full Paper