April 1, 2026International Journal of Implant Dentistry1 citationsOpen Access

Accuracy of dynamic computer-assisted implant surgery among novice operators using three different patient registration methods: an in-vitro study

RYRyo YamamotoTNToshiki NojiriDYDaichi Yoshida

Key Points

  • This research aims to investigate the influence of various registration methods on the accuracy of implant placement by novice operators using dynamic computer-assisted implant surgery.
  • Assessed three registration methods: surface-based (ND), marker-based (XC), and pair-point (XM) in-vitro.
  • Five novice dental operators placed 25 implants per group in maxillary models.
  • Used cone-beam computed tomography for measuring deviations at entry points, apex, depth, and angle.
  • Performed statistical analyses to compare differences across groups.
  • Mean deviations at implant entry were 0.97 mm (ND), 0.68 mm (XC), 0.72 mm (XM).
  • Apex deviations were 1.33 mm (ND), 0.78 mm (XC), 0.90 mm (XM).
  • Angular deviation was highest in ND (3.16°), significantly different from XC (1.18°) and XM (0.97°).
  • Average procedural time was longest in ND, shortest in XM, with significant differences observed.

Abstract

Abstract Introduction Accurate implant placement with computer-assisted implant surgery (CAIS) is critical to ensuring long-term success. Dynamic computer-assisted implant surgery (d-CAIS) enhances surgical precision through real-time feedback; however, its accuracy and procedural efficiency when used by novice operators remain insufficiently investigated. This study evaluated how different registration methods in d-CAIS influence implant placement accuracy and procedural time when performed by novice operators. Materials and methods In this in vitro study, three registration methods were assessed (surface-based registration: ND, marker-based registration: XC, and pair-point registration: XM groups). Five novice operators, defined as dentists with less than five years of implant experience, placed 25 implants per group (75 total) in partially edentulous maxillary models. Postoperative cone-beam computed tomography scans were used to measure deviations at the implant entry point, apex, vertical depth, and angle. Statistical analyses were performed to compare group differences. Results Mean three-dimensional deviations at the implant entry point were 0.97 mm (ND), 0.68 mm (XC), and 0.72 mm (XM); at the apex: 1.33 mm, 0.78 mm, and 0.90 mm, respectively. Vertical depth deviations at the apex were comparable across groups: 0.62 mm (ND), 0.51 mm (XC), and 0.54 mm (XM). Angular deviation was highest in the ND group (3.16°) compared to the XC (1.18°) and XM (0.97°) groups, with significant differences observed between ND and both XC and XM. Average procedural time was longest in the ND group and shortest in the XM group, with statistically significant differences between ND and the other two groups. Conclusions In novice operators, d-CAIS enabled stable control of implant entry point position and insertion depth regardless of the registration method used. In contrast, angular accuracy and procedural efficiency were influenced by registration strategies and system-related characteristics. These findings suggest that selection of appropriate registration methods may play an important role in optimizing accuracy and workflow efficiency during the early learning phase of d-CAIS.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yamamoto et al. (2026) studied this question.

synapsesocial.com/papers/69cd7b345652765b073a91a8https://doi.org/10.1186/s40729-026-00666-6
Ask AI
Helpful
Bookmark
Share
View Full Paper