April 4, 2026JACOW0 citationsOpen Access

SPring-8 BL12B2 Attenuator Design

View Full Paper
MHMing-Ying HsuBCBo-Yi ChenGYGung-Chian Yin

Key Points

  • This project aims to design an effective attenuator for the BL12B2 beamline to support advanced X-ray experiments.
  • Designed an attenuator featuring nine filters for X-ray applications.
  • Implemented a cooling system through the chamber wall.
  • Developed a pneumatic actuator to position filters accurately.
  • Tested filter carriers capable of absorbing 100 W at a maximum temperature of 75 °C.
  • Successfully installed the attenuator by April 2025.
  • Demonstrated the ability of the attenuator to support high temperatures and maintain optimal functioning during experiments.

Abstract

The light source of the BL12B2 beamline is one of the bending magnets in SPring-8; with this beamline, scientists can conduct experiments in X-ray absorption spectroscopy, high-resolution X-ray scattering, protein crystallography, and micro-beam scattering. The SPring-8-II will undergo an upgrade in the next few years. The attenuator, designed for the future upgrade of BL12B2, features nine filters and is cooled by the chamber wall. Each filter carrier can absorb 100 W, and the carrier's maximum temperature is lower than 75 °C when the wall temperature is 25 °C. The attenuator also provides the pumping station function; it has a 6" port for the ion and turbo pump. The attenuator filter is driven by a pneumatic actuator, which positions the filter on the beam and in the cooling position. This attenuator was already installed in the SPring-8 BL12B2 beamline in April 2025.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hsu et al. (2026) studied this question.

synapsesocial.com/papers/69d0aee0659487ece0fa4b46https://doi.org/10.18429/jacow-medsi2025-tup52
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Test bench for development of cooling mechanism of the first optical crystal towards SPring-8-II2026
  2. 2Beam-induced heating on the sector gate valve in the SPring-8-II storage ring2026
  3. 3Verification of SPring-8-II vacuum system prototype chamber2026
  4. 4Design of a damping wiggler at SPring-8-II as a high-energy X-ray source2026