PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 5, 2026Water Science & Technology1 citationsOpen Access

Experimental comparison of rainfall simulation methods for urban stormwater management research

View Full Paper
RZRachel Neleah van ZylILIone Loots

Key Points

  • The research aims to compare two types of rainfall simulators for urban stormwater management applications.
  • Conducted a side-by-side comparison of pressurised and drop-forming simulators.
  • Created a controlled indoor setup with specified rainfall area and drop height.
  • Evaluated simulators based on intensity, uniformity, drop size distribution, and drop velocity.
  • Pressurised system produced rainfall intensities of 23.9 to 109.7 mm/h.
  • Drop-forming system achieved intensities of 4.5–21.0 mm/h.
  • Uniformity coefficients were higher for the pressurised system (up to 96.4%) compared to the drop-forming system (94.8%).
  • D50 raindrop sizes differed, with pressurised averaging 0.8 to 1.2 mm and drop-forming at 1.7 mm.
  • High-intensity focus limits the pressurised system, while the drop-forming system provides broader applicability.

Abstract

ABSTRACT Side-by-side comparison of a Pressurised (PRS) and Drop-Forming Rainfall Simulator (DRS), with icons indicating intensity, uniformity, drop size, and velocity. PRS suits high-intensity studies; DRS offers broader versatility. Rainfall simulators are typically categorised as either pressurised or drop-forming systems, each offering distinct advantages depending on the research application. This study presents a comparative experimental analysis of a pressurised nozzle-based rainfall simulator and a drop-forming needle-based rainfall simulator, assessing their suitability for urban stormwater management research. Both setups were constructed indoors with a 1.5 × 1.5 m rainfall area and a 2.3 m raindrop fall height. The simulators were evaluated based on rainfall intensity, spatial uniformity, drop size distribution and drop velocity. The pressurised system produced intensities from 23.9 to 109.7 mm/h, while the drop-forming system achieved 4.5–21.0 mm/h. Uniformity coefficients ranged from 81.2 to 93.3% (cups) and 86.6 to 96.4% (trays) for the pressurised system, and 85.7% (cups) and 94.8% (trays) for the drop-forming system. D50 raindrop sizes ranged from 0.8 to 1.2 mm for the pressurised system and 1.7 mm for the drop-forming system. Estimated median drop velocities ranged from 82.5 to 98.5% of terminal velocity. While both systems replicated key rainfall characteristics, the pressurised simulator was limited to high-intensity events. The drop-forming simulator offered finer control and broader applicability, supporting its use in urban hydrology and stormwater management research.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zyl et al. (2026) studied this question.

synapsesocial.com/papers/69d1fe07a79560c99a0a4841https://doi.org/10.2166/wst.2026.249
Ask AI
Helpful
Bookmark
Share
View Full Paper