PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 22, 2019Circulation Arrhythmia and Electrophysiology252 citations

Smartwatch Performance for the Detection and Quantification of Atrial Fibrillation

View Full Paper
JWJeremiah WasserlaufCYCindy YouRPRuchi Patel

Structured PICO

Does an AF-sensing watch accurately detect and quantify atrial fibrillation episodes compared to an insertable cardiac monitor in patients with paroxysmal AF?

P
Population
24 patients with insertable cardiac monitors (ICMs) and a history of paroxysmal AF. Excluded subjects with >50% false-positive AF episodes on ICM.
I
Intervention
AF-sensing watch (AFSW; Apple Watch with KardiaBand) utilizing the SmartRhythm 2.0 convolutional neural network
C
Comparator
Simultaneous recordings from an insertable cardiac monitor (ICM; Reveal LINQ)
O
Outcome
Sensitivity of the AFSW for AF episodes ≥1 hoursurrogate

A smartwatch paired with a convolutional neural network demonstrated high sensitivity for detecting atrial fibrillation episodes ≥1 hour compared to an insertable cardiac monitor, suggesting utility for noninvasive long-term AF surveillance.

Abstract

Background Atrial fibrillation (AF) burden and duration appear to be related to stroke risk. A wearable consumer electronic device could provide long-term assessment of these measures inexpensively and noninvasively. This study compares the accuracy of an AF-sensing watch (AFSW; Apple Watch with KardiaBand) with simultaneous recordings from an insertable cardiac monitor (ICM; Reveal LINQ). Methods SmartRhythm 2.0, a convolutional neural network, was trained on anonymized data of heart rate, activity level, and ECGs from 7500 AliveCor users. The network was validated on data collected in 24 patients with ICMs and a history of paroxysmal AF who simultaneously wore the AFSW with SmartRhythm 0.1 software. The primary outcome was sensitivity of the AFSW for AF episodes ≥1 hour. Secondary end points included sensitivity of the AFSW for detection of AF by subject and sensitivity for total AF duration across all subjects. Subjects with >50% false-positive AF episodes on ICM were excluded. Results We analyzed 31 348.9 hours (mean (SD), 11.3 (4.4) hours/day) of simultaneous AFSW and ICM recordings in 24 patients. The ICM detected 82 episodes of AF ≥1 hour while the AFSW was worn, with a total duration of 1127.1 hours. Of these, the SmartRhythm 2.0 neural network detected 80 episodes (episode sensitivity, 97.5%) with a total duration of 1101.1 hours (duration sensitivity, 97.7%). Three of the 18 subjects with AF ≥1 hour had AF only when the watch was not being worn (patient sensitivity, 83.3%; or 100% during time worn). Positive predictive value for AF episodes was 39.9%. Conclusions An AFSW is highly sensitive for detection of AF and assessment of AF duration in an ambulatory population when compared with an ICM. Such devices may represent an inexpensive, noninvasive approach to long-term AF surveillance and management.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wasserlauf et al. (2019) studied this question.

synapsesocial.com/papers/69d6d09a8dca315383ed92a8https://doi.org/10.1161/circep.118.006834
Ask AI
Helpful
Bookmark
Share
View Full Paper