PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 31, 2018Dental Materials Journal24 citationsOpen Access

Proximal contact tightness of class Ⅱ bulk-fill composite resin restorations: An in vitro study

HEHassan El-ShamyHSHelal SonbulNTNajla Al Turkestani

Key Points

Key points are not available for this paper at this time.

Abstract

This study investigated the effect of bulk-fill composites on proximal contact tightness (PCT) of composite restorations using different matrix systems. 150/standardized-MO-ivorine cavity preparations were divided into 5 groups; Smart Dentin Replacement (SDR), SonicFill (SF), Tetric EvoCeram Bulk-Fill (TEB), G-ænial Universal Flo (GF) and Tetric EvoCeram (TE). Each group was subdivided into 3 sub-groups (n=10); Dixieland band in Tofflemire retainer, FenderMate and Palodent plus matrix systems. PCT was measured 24 h post-curing using Tooth Pressure Meter. PCT means were calculated and statistically-analyzed using ANOVA and Tukey's post-hoc test (p<0.05). Means and SD of PCT for Tofflemire subgroup were: 1.75(0.13), 3.21(0.1), 3.06(0.19), 2.49(0.21) and 3.18(0.1) for (SDR), (SF), (TEB), (GF) and (TE), respectively. Using FenderMate, values were: 1.87(0.08), 3.35(0.12), 3.17(0.16), 2.64(0.1) and 3.26(0.11) for (SDR), (SF), (TEB), (GF) and (TE), respectively, while with Palodentplus; 3.16(0.17), 4.23(0.11), 4.1(0.1), 3.46(0.17) and 3.98(0.1) for (SDR), (SF), (TEB), (GF) and (TE), respectively. ANOVA revealed significant differences (p<0.05) between all samples except between (SF), (TEB) and (TE) and also significant difference between Palodentplus and two subgroups. Effect of bulk-fill composites on PCT is material dependent. Separation ring is recommended for proper PCT.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

El-Shamy et al. (2018) studied this question.

synapsesocial.com/papers/69d73ac2aa68b335b4f308d0https://doi.org/10.4012/dmj.2017-279
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Influence of matrix systems on proximal contact tightness of 2- and 3-surface posterior composite restorations in vivo2011 · 73 citations
  2. 2Dental Floss Selection and Its Impact on Evaluation of Interproximal Contacts in Licensure Exams2014 · 19 citations
  3. 3Bulk-Fill Resin Composites: Polymerization Contraction, Depth of Cure, and Gap Formation2014 · 301 citations
  4. 4Gingival Sequela from a Retained Piece of Dental Floss1983 · 27 citations
  5. 5Influence of rubber-dam on the reconstruction of proximal contacts with adhesive tooth-colored restorations.2001 · 14 citations