Reliability of Gas Exchange Measurements from Two Different Spiroergometry Systems

View Full Paper
TMTim MeyerTGThomas GeorgCBChandler A. Becker

Structured PICO

Are the MetaMax I and MetaLyzer 3B spiroergometric systems reliable for gas exchange measurements during exercise testing in healthy subjects?

P
Population
23 healthy subjects (age: 25+/-5 years; weight: 71+/-10 kg; peak oxygen uptake: 55+/-9 ml x min(-1) x kg(-1))
I
Intervention
Gas exchange measurements using a portable mixing chamber system (MetaMax I) and a stationary breath-by-breath spiroergometric device (MetaLyzer 3B) during consecutive identical bicycle ergometer ramp exercise tests
C
Comparator
Consecutive identical tests (test 1 vs test 2) to assess reliability
O
Outcome
Intra-class reliability coefficients for oxygen uptake (VO2), carbon dioxide output (VCO2), and minute ventilation (VE)surrogate

Both the portable MetaMax I and stationary MetaLyzer 3B spiroergometric systems are highly reliable instruments for measuring gas exchange during exercise testing.

Abstract

Reliability of two different spiroergometric systems was investigated by comparing gas exchange measurements from two consecutive identical bicycle ergometer ramp exercise tests which were conducted after an initial habituation trial. Twenty-three healthy subjects (age: 25+/-5 years; weight: 71+/-10 kg; peak oxygen uptake: 55+/-9 ml x min(-1) x kg(-1)) took part in the study. One apparatus was a portable mixing chamber system (MetaMax I, Cortex, Leipzig, Germany), the other one a stationary spiroergometric device measuring in the breath-by-breath mode (MetaLyzer 3B, Cortex). There were no relevant systematic changes in gas exchange measurements and heart rate from test 1 to test 2. Intra-class reliability coefficients were 0.984 (oxygen uptake = VO2), 0.977 (carbon dioxide output = VCO2), and 0.973 (minute ventilation = VE) for the MetaMax I, and 0.969 (VO2), 0.964 (VCO2), and 0.953 (VE) for the MetaLyzer 3B. Bland-Altman plots revealed a slightly smaller variability of MetaLyzer 3B measurements compared to those of MetaMax I. It is concluded that the spiroergometric devices MetaMax I and MetaLyzer 3B represent reliable instruments for exercise testing in sports medical routine and research. This is important to decide if longitudinal changes in gas exchange measurements represent clinically meaningful differences in performance or merely inconsistencies of the measuring tool.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Meyer et al. (2001) studied this question.