PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 28, 2006Magnetic Resonance in Medicine173 citations

Time‐resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging

View Full Paper
RBRoland BammerTHThomas A. HopeMAMurat Aksoy

Key Points

Key points are not available for this paper at this time.

Abstract

Exact knowledge of blood flow characteristics in the major cerebral vessels is of great relevance for diagnosing cerebrovascular abnormalities. This involves the assessment of hemodynamically critical areas as well as the derivation of biomechanical parameters such as wall shear stress and pressure gradients. A time-resolved, 3D phase-contrast (PC) MRI method using parallel imaging was implemented to measure blood flow in three dimensions at multiple instances over the cardiac cycle. The 4D velocity data obtained from 14 healthy volunteers were used to investigate dynamic blood flow with the use of multiplanar reformatting, 3D streamlines, and 4D particle tracing. In addition, the effects of magnetic field strength, parallel imaging, and temporal resolution on the data were investigated in a comparative evaluation at 1.5T and 3T using three different parallel imaging reduction factors and three different temporal resolutions in eight of the 14 subjects. Studies were consistently performed faster at 3T than at 1.5T because of better parallel imaging performance. A high temporal resolution (65 ms) was required to follow dynamic processes in the intracranial vessels. The 4D flow measurements provided a high degree of vascular conspicuity. Time-resolved streamline analysis provided features that have not been reported previously for the intracranial vasculature.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bammer et al. (2006) studied this question.

synapsesocial.com/papers/69d81aed5c3030ff03d19533https://doi.org/10.1002/mrm.21109
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Concomitant gradient terms in phase contrast MR: Analysis and correction1998 · 547 citations
  2. 2Numerical recipes in C1994 · 15,352 citations
  3. 3Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment2003 · 3,924 citations
  4. 4Are some strokes preventable? The potential role of transcranial doppler in transient ischaemic attacks of carotid origin2005 · 29 citations
  5. 5Encoding strategies for three‐direction phase‐contrast MR imaging of flow1991 · 451 citations