PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 10, 2026Annals of Internal Medicine3 citations

Multisite External Validation of a Clinical Screening Tool for Interpersonal Firearm Violence Risk

View Full Paper
JGJason E. GoldstickPCPatrick M. CarterMDM. Kit Delgado

Key Points

  • This research aims to validate a screening tool designed to identify individuals at risk for interpersonal firearm violence.
  • Conducted a prospective longitudinal study in four emergency departments.
  • Included adults aged 18 to 24 who sought treatment for any reason.
  • Measured firearm violence incidence and assessed baseline SaFETy scores along with demographic and health-related covariates.
  • Among 1506 participants, 6.5% reported firearm violence 12 months later.
  • The SaFETy score demonstrated an area under the ROC curve of 0.78, indicating good predictive ability.
  • Higher SaFETy scores correlated with increased rates of firearm violence.

Abstract

BACKGROUND: Screening tools for interpersonal firearm violence (FV) are needed to facilitate prevention. OBJECTIVE: To validate the 4-item, 10-point SaFETy (Serious fighting, Friend weapon carrying, community Environment, and firearm Threats) score. DESIGN: Prospective longitudinal study. SETTING: 4 level 1 emergency departments (EDs) in 3 cities. PARTICIPANTS: Adults aged 18 to 24 years seen in an ED for any reason. MEASUREMENTS: FV (shooting someone or being shot) 12 months after baseline from self-report and medical record review, SaFETy score, and self-reported baseline covariates (demographic characteristics; baseline assault injury; violence-related ED use in the past 6 months; drug misuse; anxiety, depression, and posttraumatic stress screening; and FV in the past 6 months). RESULTS: Among 1506 participants (61.4% female; mean age, 21.3 years; 3.8% with assault injury at baseline), 12-month FV could be ascertained in 1122 (74.5%); of those, 73 (6.5%) had 12-month FV. For baseline SaFETy scores of 0, 1 to 5, and 6 or greater, 12-month FV rates were 1.8% (12 of 654), 12.1% (49 of 406), and 25.0% (10 of 40), respectively. The area under the receiver-operating characteristic (ROC) curve (AUC) for the score was 0.78 (95% CI, 0.72 to 0.83). The optimal ROC cut point was a SaFETy score greater than 0, with a sensitivity of 83.1% and specificity of 62.4%; a SaFETy score greater than 4 optimized positive predictive value (31.6%). Logistic regression of 12-month FV, including the full covariate set, examined estimated risks for patients grouped by SaFETy score and found that model-based predictions underestimated risk among those with SaFETy scores of 0 and overestimated risk among those with SaFETy scores of 1 to 5 or 6 or greater. Adding the SaFETy score to the full covariate set improved the predictions' AUC (0.84 vs. 0.81; LIMITATION: Outcomes were primarily self-reported, and the highest-risk subsamples were more likely to have missing data. CONCLUSION: The SaFETy score predicts FV risk in general samples of young adults in the ED. A comprehensive covariate set, involving factors that are difficult or intrusive to measure, did not reproduce the SaFETy score's risk gradient or explain its discriminatory power, suggesting that the score provides distinct predictive information. PRIMARY FUNDING SOURCE: Centers for Disease Control and Prevention.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Goldstick et al. (2026) studied this question.

synapsesocial.com/papers/69d892886c1944d70ce03f5bhttps://doi.org/10.7326/annals-25-03950
Ask AI
Helpful
Bookmark
Share
View Full Paper