April 10, 2026Polymers0 citationsOpen Access

Quantitative Assessment of SBS-Modifier Content in Bituminous Binders Using Infrared Spectroscopy

View Full Paper
SASaltanat AshimovaYAYerik AmirbayevAZAdiya Zhumagulova

Key Points

  • The study aims to quantitatively assess the concentration of styrene-butadiene-styrene (SBS) in polymer-modified bitumen (PMB).
  • Developed a Fourier Transform Infrared Spectroscopy—Attenuated Total Reflectance (FTIR-ATR) method.
  • Prepared calibration PMB samples containing 1–4% SBS.
  • Tested physical and mechanical properties of PMB samples.
  • Analyzed spectral data to identify key absorption bands.
  • Established a linear correlation between SBS content and IR absorption features.
  • Demonstrated high accuracy and reproducibility in determining polymer mass fraction.
  • Found that 3–4% SBS levels optimize performance-related properties like softening point and elasticity.

Abstract

Polymer-modified bituminous binders are widely used in road construction due to their enhanced mechanical performance; however, the effectiveness of these materials critically depends on the actual concentration of polymer modifiers, particularly styrene-butadiene-styrene (SBS). This study aims to develop and validate a rapid, reproducible Fourier Transform Infrared Spectroscopy—Attenuated Total Reflectance (FTIR-ATR) spectroscopy method for the quantitative determination of SBS content in polymer-modified bitumen (PMB). Since, to date, there is no clearly defined method for controlling the quantitative content of polymers in PMB, this creates difficulties in accepting the roadway into operation. Calibration PMB samples containing 1–4% SBS were prepared, tested for physical and mechanical properties, and analyzed spectroscopically to identify characteristic absorption bands at 966 cm−1 and 699–760 cm−1. A first-order calibration model was constructed to relate peak intensity to polymer concentration. The results demonstrate a clear linear correlation between SBS content and IR absorption features, confirming the suitability of FTIR as an instrumental method for routine laboratory control. Application of the model allowed determination of actual polymer mass fraction with high accuracy and reproducibility. The findings also showed that increased SBS levels improve softening point, elasticity, and low-temperature resistance, with 3–4% representing a performance-optimal range. Overall, the proposed FTIR-based approach provides an objective and efficient tool for quality control of polymer-modified binders and supports broader standardization efforts in the field.