October 18, 2023JAMA Cardiology69 citationsOpen Access

Lead Extraction and Mortality Among Patients With Cardiac Implanted Electronic Device Infection

View Full Paper
SPSean D. PokorneyLZLindsay ZepelMGMelissa A. Greiner

Structured PICO

Does lead extraction reduce mortality in patients with Cardiac Implanted Electronic Device infection?

P
Population
Patients with Cardiac Implanted Electronic Device (CIED) infection
I
Intervention
Lead extraction
C
Comparator
No extraction
O
Outcome
Mortality (death)hard clinical

Lead extraction in patients with CIED infection is associated with reduced mortality, highlighting the need for improved adherence to guideline-directed care.

Abstract

In this study, a minority of patients with CIED infection underwent extraction. Extraction was associated with a lower risk of death compared with no extraction. The findings suggest a need to improve adherence to guideline-directed care among patients with CIED infection.