PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 5, 2023NeuroImage92 citationsOpen Access

Enabling ambulatory movement in wearable magnetoencephalography with matrix coil active magnetic shielding

NHNiall HolmesMRMolly ReaRHRyan M. Hill

Key Points

Key points are not available for this paper at this time.

Abstract

The ability to collect high-quality neuroimaging data during ambulatory participant movement would enable a wealth of neuroscientific paradigms. Wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs) has the potential to allow participant movement during a scan. However, the strict zero magnetic field requirement of OPMs means that systems must be operated inside a magnetically shielded room (MSR) and also require active shielding using electromagnetic coils to cancel residual fields and field changes (due to external sources and sensor movements) that would otherwise prevent accurate neuronal source reconstructions. Existing active shielding systems only compensate fields over small, fixed regions and do not allow ambulatory movement. Here we describe the matrix coil, a new type of active shielding system for OPM-MEG which is formed from 48 square unit coils arranged on two planes which can compensate magnetic fields in regions that can be flexibly placed between the planes. Through the integration of optical tracking with OPM data acquisition, field changes induced by participant movement are cancelled with low latency (25 ms). High-quality MEG source data were collected despite the presence of large (65 cm translations and 270° rotations) ambulatory participant movements.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Holmes et al. (2023) studied this question.

synapsesocial.com/papers/69dbb355f7e0c66ced835f14https://doi.org/10.1016/j.neuroimage.2023.120157
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A lightweight magnetically shielded room with active shielding2022 · 127 citations
  2. 2Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system2021 · 164 citations
  3. 3Hyperscanning: Simultaneous fMRI during Linked Social Interactions2002 · 858 citations
  4. 4Measures to reduce the residual field and field gradient inside a magnetically shielded room by a factor of more than 102013 · 49 citations
  5. 5Multi-channel whole-head OPM-MEG: Helmet design and a comparison with a conventional system2020 · 298 citations