PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 1979Journal of the Optical Society of America14 citations

Duration thresholds for chromatic stimuli

View Full Paper
JPJoel PokornyRBRichard W. BowenDWDelwin T. Williams

Key Points

Key points are not available for this paper at this time.

Abstract

The duration necessary to detect chromatic stimuli was measured for wavelengths between 463 and 620 nm. Stimuli were presented either in hue substitution (replacement of white by a chromatic stimulus of matched luminance) or as increments. Two observers viewed a 1 degrees 45' homogeneous white field. A trial consisted of replacement of the central 40' of the field by a chromatic stimulus. In substitution mode the white field was 2.4 cd/m2., the chromatic replacement was of matched luminance using heterochromatic flicker photometry (HFP). In increment mode, the white field was decreased to 1.2 cd/m2., the chromatic replacement remained at 2.4 cd/m2. In substitution mode, duration threshold varied from approximately 3--4 ms for the spectral extremes to 45--66 ms at 570 nm. Detected stimuli were always seen as a change in chromaticity. In increment mode, thresholds were in the 2--4 ms range with no dependence upon spectral composition. Detected stimuli were seen either as changes in chromaticity or brightness. A control experiment indicated that HFP did establish equivalent luminance for the hue substitution mode. We conclude that duration thresholds in substitution mode reveal chromatic processing channels; duration thresholds in increment mode are mediated by chromatic and/or achromatic processing channels.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pokorny et al. (1979) studied this question.

synapsesocial.com/papers/69dc489d4f901957bec1006bhttps://doi.org/10.1364/josa.69.000103
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Wavelength Effect on Visual Latency1972 · 31 citations
  2. 2Saturation and the Foveal Achromatic Interval*1969 · 30 citations
  3. 3Use of Pulsed Magnetic Fields to Measure the Faraday Effect in Gases1969 · 12 citations
  4. 4Luminance and opponent-color contributions to visual detection and adaptation and to temporal and spatial integration1976 · 439 citations
  5. 5Chromatic two-pulse resolution with and without luminance transients*1977 · 21 citations