September 1, 2015Review of Scientific Instruments34 citationsOpen Access

A fully integrated standalone portable cavity ringdown breath acetone analyzer

MSMeixiu SunCJChenyu JiangZGZhiyong Gong

Key Points

Key points are not available for this paper at this time.

Abstract

Breath analysis is a promising new technique for nonintrusive disease diagnosis and metabolic status monitoring. One challenging issue in using a breath biomarker for potential particular disease screening is to find a quantitative relationship between the concentration of the breath biomarker and clinical diagnostic parameters of the specific disease. In order to address this issue, we need a new instrument that is capable of conducting real-time, online breath analysis with high data throughput, so that a large scale of clinical test (more subjects) can be achieved in a short period of time. In this work, we report a fully integrated, standalone, portable analyzer based on the cavity ringdown spectroscopy technique for near-real time, online breath acetone measurements. The performance of the portable analyzer in measurements of breath acetone was interrogated and validated by using the certificated gas chromatography-mass spectrometry. The results show that this new analyzer is useful for reliable online (online introduction of a breath sample without pre-treatment) breath acetone analysis with high sensitivity (57 ppb) and high data throughput (one data per second). Subsequently, the validated breath analyzer was employed for acetone measurements in 119 human subjects under various situations. The instrument design, packaging, specifications, and future improvements were also described. From an optical ringdown cavity operated by the lab-set electronics reported previously to this fully integrated standalone new instrument, we have enabled a new scientific tool suited for large scales of breath acetone analysis and created an instrument platform that can even be adopted for study of other breath biomarkers by using different lasers and ringdown mirrors covering corresponding spectral fingerprints.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Sun et al. (2015) studied this question.

synapsesocial.com/papers/69dcc25bec98b63720133306https://doi.org/10.1063/1.4930121
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Open-path trace gas detection of ammonia based on cavity-enhanced absorption spectroscopy2000 · 86 citations
  2. 2Deuterium substituted amphetamine as an internal standard in a gas chromatographic/mass spectrometric (GC/MS) assay for amphetamine1973 · 43 citations
  3. 3Variation in volatile organic compounds in the breath of normal humans1999 · 739 citations
  4. 4Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources1988 · 1,614 citations
  5. 5Cavity ring-down spectroscopy: Experimental schemes and applications2000 · 1,017 citations