PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 29, 2010Analytical Chemistry81 citations

Thin Layer Coulometry with Ionophore Based Ion-Selective Membranes

View Full Paper
EGEwa Grygołowicz‐PawlakEBEric Bakker

Key Points

Key points are not available for this paper at this time.

Abstract

We are demonstrating here for the first time a thin layer coulometric detection mode for ionophore based liquid ion-selective membranes. Coulometry promises to achieve the design of robust, calibration free sensors that are especially attractive for applications where recalibration in situ is difficult or undesirable. This readout principle is here achieved with porous polypropylene tubing doped with the membrane material and which contains a chlorinated silver wire in the inner compartment, together with the fluidically delivered sample solution. The membrane material consists of the lipophilic plasticizer dodecyl 2-nitrophenyl ether, the lipophilic electrolyte ETH 500, and the calcium ionophore ETH 5234. Importantly and in contrast to earlier work on voltammetric liquid membrane electrodes, the membrane also contains a cation-exchanger salt, KTFPB. This renders the membrane permselective and allows one to observe open circuit potentiometric responses for the device, which is confirmed to follow the expected Nernstian equation. Moreover, as the same cationic species is now potential determining at both interfaces of the membrane, it is possible to use rapidly diffusing and/or thin membrane systems where transport processes at the inner and outer interface of the membrane do not perturb each other or the overall composition of the membrane. The tubing is immersed in an electrolyte solution where the counter and working electrode are placed, and the potentials are applied relative to the measured open circuit potentials. Exhaustive current decays are observed in the range of 10 to 100 muM calcium chloride. The observed charge, calculated as integrated currents, is linearly dependent on concentration and forms the basis for the coulometric readout of ion-selective membrane electrodes.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Grygołowicz‐Pawlak et al. (2010) studied this question.

synapsesocial.com/papers/69dcc3f2f729781886359740https://doi.org/10.1021/ac100524z
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Complete Electrolysis Using a Microflow Cell with an Oil/Water Interface2002 · 45 citations
  2. 2Neutral carrier based ion-selective electrode for the determination of total calcium in blood serum1981 · 185 citations
  3. 3Electroanalysis and Coulometric Analysis1966 · 10 citations
  4. 4Inside Cover: A Molecular Solomon Link (Angew. Chem. Int. Ed. 1‐2/2007)2007 · 239 citations
  5. 5Pulsed Galvanostatic Control of Ionophore-Based Polymeric Ion Sensors2003 · 116 citations