June 23, 2023SHILAP Revista de lepidopterología56 citationsOpen Access

Wearable Technologies for Electrodermal and Cardiac Activity Measurements: A Comparison between Fitbit Sense, Empatica E4 and Shimmer GSR3+

VRVincenzo RoncaAMAna C. Martinez-LevyAVAlessia Vozzi

Structured PICO

Does the Fitbit Sense provide reliable EDA and PPG measurements compared to research-grade devices (Empatica E4 and Shimmer GSR3+) in resting participants?

P
Population
12 participants
I
Intervention
Fitbit Sense (consumer wearable device)
C
Comparator
Empatica E4 (research-graded wearable) and Shimmer GSR3+ (laboratory device)
O
Outcome
Reliability and correlation of Electrodermal Activity (EDA) and Photoplethysmographic (PPG) data during multiple resting conditionssurrogate

While consumer wearables like the Fitbit Sense show significant correlation with research-grade devices for EDA and PPG measurements, their overall reliability remains significantly lower.

Abstract

The capability of measuring specific neurophysiological and autonomic parameters plays a crucial role in the objective evaluation of a human's mental and emotional states. These human aspects are commonly known in the scientific literature to be involved in a wide range of processes, such as stress and arousal. These aspects represent a relevant factor especially in real and operational environments. Neurophysiological autonomic parameters, such as Electrodermal Activity (EDA) and Photoplethysmographic data (PPG), have been usually investigated through research-graded devices, therefore resulting in a high degree of invasiveness, which could negatively interfere with the monitored user's activity. For such a reason, in the last decade, recent consumer-grade wearable devices, usually designed for fitness-tracking purposes, are receiving increasing attention from the scientific community, and are characterized by a higher comfort, ease of use and, therefore, by a higher compatibility with daily-life environments. The present preliminary study was aimed at assessing the reliability of a consumer wearable device, i.e., the Fitbit Sense, with respect to a research-graded wearable, i.e., the Empatica E4 wristband, and a laboratory device, i.e., the Shimmer GSR3+. EDA and PPG data were collected among 12 participants while they performed multiple resting conditions. The results demonstrated that the EDA- and PPG-derived features computed through the wearable and research devices were positively and significantly correlated, while the reliability of the consumer device was significantly lower.