PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 18, 2026Physics of Plasmas0 citations

A calibrated experimental platform at the LMJ facility to produce and characterize high radiant energy xenon and krypton x-ray sources

View Full Paper
CBC. BaccouAGA. GrolleauGBG. Boutoux

Key Points

  • The aim is to develop a platform for producing and characterizing x-ray sources from xenon and krypton for material studies.
  • Developed a calibrated platform at the Laser MégaJoule facility.
  • Utilized broadband spectrometers for time-resolved x-ray power measurements.
  • Analyzed x-ray emission spectra to determine plasma characteristics.
  • Conducted multiple experimental campaigns with varying laser energies.
  • Achieved 3713 ± 740 J/sr radiant energy for the xenon source with an 18% conversion efficiency.
  • Demonstrated 381 ± 106 J/sr radiant energy for the krypton source with a 2% conversion efficiency.
  • Evaluated x-ray source yields as a function of laser energy.

Abstract

At the Laser MégaJoule facility, we have recently developed a calibrated experimental platform to produce and characterize high-fluence and multi-kiloelectronVolt nanosecond x-ray sources. Such sources are used for radiographic imaging or for studying the effects of intense x-ray irradiation on materials. Broadband spectrometers provide time-resolved x-ray powers measurements; an x-ray spectrometer, recently implemented, provides well resolved x-ray emission spectra, which can be used to infer plasma characteristics such as the electron temperature, by relying on atomic physics calculations with the SAPHyR code. Xenon and krypton gas pipe targets were chosen for their peaked emission between 4 and 6 keV (L-shell line transitions) and at 13 keV (K-shell line transitions), respectively. After a proof-of-concept carried out in 2019, several experimental campaigns followed, in which the laser energy was gradually increased. We have conducted a comprehensive evaluation of all results, allowing us to evaluate the x-ray radiant energy and the source yields as a function of laser energy. For the xenon source, we demonstrated up to 3713 ± 740 J/sr in the L-band, i.e., a laser-to-x-ray conversion efficiency (CE) of 18%. For the krypton source, we demonstrated 381 ± 106 J/sr in the K-band, corresponding to CE equal to 2%, as the K-shell line excitations require more laser energy.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Baccou et al. (2026) studied this question.

synapsesocial.com/papers/69e3205140886becb653f660https://doi.org/10.1063/5.0321753
Ask AI
Helpful
Bookmark
Share
View Full Paper