PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 19, 2026Drones1 citationsOpen Access

Comparative Evaluation of Segmentation-Based and Pose-Assisted Head Temperature Estimation from UAS Thermal Imagery Under Controlled Conditions

View Full Paper
OAOwais AhmedJGJustin GuyeMTM. Hassan Tanveer

Key Points

  • The central aim is to compare head temperature estimation methods using UAS thermal imagery.
  • Conducted a comparative evaluation of object detection architectures.
  • Utilized segmentation-based and pose-assisted localization strategies.
  • Estimated head temperatures using radiometric metadata from thermal images.
  • Assessed performance under varying flight altitudes.
  • Pose-assisted method produced head temperature estimates within the expected physiological range.
  • Segmentation-based approach yielded higher temperature values due to external factors.
  • Cross-domain inference with YOLOv11 models enabled reliable human detection under controlled conditions.

Abstract

This paper presents a vision-based framework for detecting humans and estimating head surface temperature from aerial thermal imagery acquired by Unmanned Aerial Systems (UAS). A comparative evaluation of recent object detection architectures was conducted to identify the most stable and reliable model for thermal human detection under varying flight altitudes. The selected framework integrates two head localization strategies, namely, segmentation-based mask slicing and pose-assisted keypoint localization, to extract head regions and compute per-pixel temperature values from radiometric metadata. The results show that cross-domain inference using pre-trained YOLOv11 models achieves reliable human detection across controlled outdoor environments. Between the two pipelines, the pose-assisted method produced temperature estimates closer to the expected human physiological range (36–38 ∘C), whereas the segmentation-based approach exhibited higher values attributable to mask boundary contamination and solar surface heating. In the absence of ground-truth validation from medical-grade sensors, these findings are characterized as relative comparisons rather than absolute accuracy claims. This study establishes a methodological foundation for future UAS-based thermal assessment systems and identifies critical calibration and validation requirements for field deployment.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ahmed et al. (2026) studied this question.

synapsesocial.com/papers/69e4739a010ef96374d8f670https://doi.org/10.3390/drones10040295
Ask AI
Helpful
Bookmark
Share
View Full Paper