April 19, 2026Otology & Neurotology0 citations

Cochlear Morphology and Its Influence on Electrode Array Proximity to Modiolus

View Full Paper
MMMoayyad MalasMAMariam AljehaniAAAbdulrahman Alsanosi

Key Points

  • The aim is to assess how cochlear morphology affects the distance between electrodes and the modiolus.
  • Evaluated cochlear anatomic parameters and their relationship with electrode-to-modiolus distance.
  • Analyzed comparisons between lateral wall electrodes in different cochlear shapes.
  • Exploratory trends were noted without quantifying statistical significance.
  • No statistically significant association found between cochlear anatomy and electrode distance.
  • Stable electrode positioning noted across variations in cochlear shape.
  • Lateral wall electrodes showed comparable distances to the modiolus regardless of cochlear morphology.

Abstract

This study reported no statistically significant association between cochlear anatomic parameters and electrode-to-modiolus distance. Lateral wall electrodes demonstrated comparable distances to the modiolus in both elliptical and round-shaped basal turn cochleae, suggesting stable positioning across anatomic variations. Although descriptive trends were observed, these findings should be interpreted as exploratory. Larger prospective studies are needed to further evaluate the influence of cochlear morphology on electrode positioning across different electrode designs.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Malas et al. (2026) studied this question.

synapsesocial.com/papers/69e473bd010ef96374d8f779https://doi.org/10.1097/mao.0000000000004921
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Dependability of Electrode to Modiolus Distance in Patients Specific Electrode Selection: A Cadaveric Model Study2024
  2. 2Curvature analysis of CI electrode arrays: a novel approach to categorize perimodiolar positions without anatomical landmarks2024 · 1 citations
  3. 3Spatial Analysis of Electrode Proximity to Lateral Wall and Its Impact on ECAP Amplitudes: An OTOPLAN-Based Study2026
  4. 4Is the Position of the Basal-Most Electrode Depending on Electrode Array Design and Influencing Postoperative Speech Perception? A Retrospective Analysis of 495 Ears2024
  5. 5Cochlear implant electrode design for safe and effective treatment2024 · 35 citations