PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 19, 2026Bioengineering0 citationsOpen Access

The Influence of Non-Thermal Plasma Treatment on Osseointegration of Endosteal Implants Presenting Decompressing Vertical Chambers

View Full Paper
SMShray MehraHSHana ShahSMSara E. Munkwitz

Key Points

  • This research aims to evaluate the effect of non-thermal plasma treatment on the osseointegration of endosteal implants with various designs.
  • Three implant systems were compared: ND, Sin, and Mp.
  • Mp implants underwent additional acid etching and non-thermal plasma treatment before implantation.
  • Histomorphometric analysis was conducted at 3 and 12 weeks post-implantation in 12 adult female sheep.
  • All groups showed newly formed woven bone at 3 weeks post-implantation.
  • By 12 weeks, signs of bone maturation and remodeling were observed.
  • Mp implants had significantly higher bone area fraction occupancy compared to ND implants at both time points.

Abstract

Current evidence suggests that achieving the desired level of osseointegration necessitates a hierarchical approach to implant design. This is particularly relevant for osseointegration around implant systems such as those presenting vertical decompression chambers and acid-etched surfaces which could further be augmented by non-thermal plasma (NTP) treatment. Three implant systems were compared in this study: (i) ND (GM Helix Acqua Implant; Neodent®, Curitiba, PR, Brazil—hybrid, acid-etched thread design treated with isotonic sodium chloride solution), (ii) Sin (Epikut Plus; S.I.N. Implant System, São Paulo, Brazil—V-shaped, acid-etched thread design treated with nano-hydroxyapatite), and (iii) Mp (Maestro; Implacil De Bortoli, São Paulo, Brazil—buttress, acid-etched thread design with decompressing vertical chambers). The ND and Sin implants were used directly as supplied by the manufacturer. For the Mp implants, the manufacturer-supplied surface was subjected to supplemental acid etching with 37% hydrochloric acid followed by Argon-based NTP treatment administered with a pulsed plasma generator prior to implantation into the iliac crest of n = 12 adult female sheep. Histomorphometric analysis was conducted at 3- and 12-week post-implantation (n = 6 sheep per time point) to assess bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). After 3 weeks in vivo, the healing chambers of all implant groups consisted predominantly of newly forming woven bone. By 12 weeks, bone maturation was observed, with the presence of remodeling sites and some areas of well-organized lamellar structures occupying the healing chambers. At both 3 and 12 weeks, the Mp implants demonstrated significantly higher BAFO values relative to ND (p = 0.015 and p = 0.008, respectively). The combination of vertical healing chambers, acid etching, and NTP treatment promoted early vascular infiltration and sustained bone deposition.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Mehra et al. (2026) studied this question.

synapsesocial.com/papers/69e4745f010ef96374d90290https://doi.org/10.3390/bioengineering13040472
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effect of Secondary Non‐Thermal Plasma Decontamination on Ethanol‐Treated Endosteal Implant Surfaces: An In Vivo Study of Osseointegration2025 · 2 citations
  2. 2Comparative Analysis of Surface Modification Techniques for Assessing Oral Implant Osseointegration: An Animal Study2024 · 5 citations
  3. 3Impact of Plasma Surface Treatment on Implant Stability and Early Osseointegration: A Retrospective Cohort Study2025 · 3 citations
  4. 4Impact of Plasma Surface Treatment on Implant Stability and Early Osseointegration: A Retrospective Cohort Study2025 · 1 citations
  5. 5In Vivo Evaluation of Laser-Textured Air Plasma in Osseointegration of Dental Implants2025