Comparative Assessment of Two Nitinol Fatigue Datasets to Support Cardiovascular Medical Device Durability

View Full Paper
JWJason D. Weaver

Key Points

  • The aim is to compare two nitinol fatigue datasets to evaluate the durability of cardiovascular medical devices.
  • Utilized two recently published nitinol fatigue datasets relevant to cardiovascular applications
  • Assessed several comparative metrics to analyze data uniformity
  • Attempted to predict high cycle fatigue strength using low cycle fatigue data
  • Identified significant variability based on the selected metrics impacting dataset comparison
  • Demonstrated that low cycle fatigue data may not reliably predict high cycle fatigue strength
  • Emphasized the need for extensive fatigue testing aligned with device lifespan

Abstract

ABSTRACT Comparisons of fatigue performance between datasets are relatively common practice, although there is not a standardized metric for conducting such analyses. In this work, two recently published nitinol fatigue datasets with relevance for cardiovascular medical devices are used to probe a range of comparative metrics. Results highlight the importance of selecting an appropriate metric as well as the importance of test planning as both can affect the final conclusion regarding the similarity of two datasets. Additionally, an unsuccessful attempt was made to predict high cycle fatigue strength based on low cycle (i.e., censored) fatigue data using a Coffin-Manson relation, which reinforces the importance of conducting fatigue tests to as many cycles as the intended device lifetime. Lessons learned from this set of analyses can inform future standards work as well as engineering practice.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jason D. Weaver (2026) studied this question.

synapsesocial.com/papers/69e9ba6b85696592c86ec991https://doi.org/10.1520/jte20250249
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Novel Fatigue-to-Fracture Technology for Super-Elastic Alloy in Cardiac Pulsatile Loading Mode2024 · 1 citations
  2. 2Guide for Finite Element Analysis (FEA) of Metallic Vascular Stents Subjected to Uniform Radial Loading2021 · 1 citations
  3. 3Test Methods for in vitro Pulsatile Durability Testing of Vascular Stents and Endovascular Prostheses2024 · 1 citations
  4. 4Standard Guide for Fatigue-to-Fracture (FtF) Methodology for Cardiovascular Medical Devices2017 · 6 citations