PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 24, 2026Neuroimage Reports2 citationsOpen Access

Comparability of Centiloid values from 18Fflutemetamol scans using seven commercial and research software

View Full Paper
ABAriane BollackASAdam J. SchwarzPBPierrick Bourgeat

Key Points

  • This research aims to evaluate how comparably Centiloid values from [18F]flutemetamol scans are derived using different software tools.
  • Analyzed data from three cohorts: test-retest, aMCI, and BioFINDER-1.
  • Processed images across seven quantification pipelines, including commercial and research tools.
  • Conducted statistical analysis including repeatability, reproducibility, and inter-software reliability.
  • High test-retest repeatability observed with bias less than 5 CL in 10 AD patients.
  • Reproducibility was strong across the aMCI dataset with R² values between 0.94-0.99.
  • Agreement between software at clinically relevant thresholds ranged from 75-100%.

Abstract

Quantification using the Centiloid (CL) scale has become a valuable information to consider when interpreting amyloid-PET images and is now implemented in several software packages. This work aims to assess the comparability of CL from 18 Fflutemetamol scans derived using several research and commercial quantification pipelines. This analysis relies on three datasets: a test-retest cohort, a group of clinically relevant patients with amnestic mild cognitive impairment (aMCI) and a subgroup from the BioFINDER-1 cohort enriched with scans with amyloid loads around potential clinical decision thresholds (0-50CL). Images from the Test-Retest and aMCI cohorts were processed across seven quantification pipelines: three commercial software platforms and four research tools, including the standard SPM8 workflow. The statistical analysis was based on three steps: 1) a repeatability analysis using the test-retest data; 2) a reproducibility analysis across all pipelines using the aMCI cohort; 3) an inter-software reliability analysis around three clinically relevant thresholds: 11, 25 and 37 CL using the aMCI and the BioFINDER-1 data. In the Test-Retest dataset composed of 10 Alzheimer's Disease (AD) patients, high test-retest repeatability and reliability were observed with an absolute bias of less than 5 CL. Within-individual coefficients of variation ranged from 2.6 to 4.4% and repeatability coefficients from ∼8 to ∼16 CL. CL quantification was generally reproducible across pipelines in a dataset of 80 aMCI individuals (R 2 in 0.94-0.99, slope in 0.98–1.03, intercept in -4, 4, but the 95% limits of agreement (LoAs) ranged between ∼±12 and ∼±21 CL. Agreement between software around the three clinically relevant thresholds was 92-100% (kappa 0.83-1) in the aMCI data (N = 80) and 75-99% (kappa 0.48-0.96) in the BioFINDER-1 subgroup (N = 110). In this study, CL quantification was shown to be robust across a range of currently available software platforms. Uncertainty estimates should always be considered when interpreting results. In clinical practice, the choice of quantification software should not impact patient management decisions.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bollack et al. (2026) studied this question.

synapsesocial.com/papers/69eb084f553a5433e34b35d6https://doi.org/10.1016/j.ynirp.2026.100343
Ask AI
Helpful
Bookmark
Share
View Full Paper