PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 24, 2026Journal of Medical Imaging and Interventional Radiology0 citationsOpen Access

Non-invasive exchange of encrusted nephrostomy tubes using a modified sheath technique: technical description and case series

WSWai Hung Lester ShiuKCKin Wong Chan

Key Points

  • This research aims to evaluate a modified sheath technique for successful nephrostomy tube exchanges in cases of encrustation.
  • Retrospective review of nephrostomy tube exchanges using the modified sheath technique.
  • Evaluated cases between February 2025 and January 2026 at a tertiary center.
  • Assessment included technical success, complications, and demographic data.
  • Achieved technical success in 19 of 20 cases (95%) of encrusted nephrostomy tubes.
  • One case reported loss of tract access due to sheath buckling and was abandoned.
  • No major procedure-related complications observed.

Abstract

Percutaneous nephrostomy (PCN) catheter exchange is commonly performed using standard over-the-wire techniques; however, exchange may be challenging or unsuccessful in the setting of catheter encrustation. Failure of nephrostomy exchange may necessitate de novo renal access, increasing procedural risk and resource utilization. We describe a modified sheath technique to facilitate catheter exchange in difficult cases. All cases of nephrostomy tube exchange performed using a modified sheath technique between February 2025 and January 2026 at a single tertiary centre were retrospectively reviewed. Patients with encrusted nephrostomy tubes in whom conventional wire-guided exchange failed were included. Procedural technique, demographic data, technical success, and complications were evaluated. Technical success was achieved in 19 of 20 cases (95%) of encrusted nephrostomy tubes using the modified sheath technique. In one case, loss of tract access occurred due to sheath buckling, and the procedure was abandoned. No major procedure-related complications were observed. Nephrostomy tube exchange using a modified sheath technique demonstrates a high technical success rate in cases of challenging encrusted nephrostomy tubes. This fluoroscopy-guided approach preserves collecting system access and may serve as a practical minimally invasive salvage option in routine interventional radiology practice.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Shiu et al. (2026) studied this question.

synapsesocial.com/papers/69eb0899553a5433e34b38d0https://doi.org/10.1007/s44326-026-00098-x
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Non-invasive removal of self-locking entrapped nephrostomy tubes2020 · 1 citations
  2. 2Salvage of a Blocked Nephrostomy Catheter Using Needle Recanalization -SURE (Sharp Urologic REcanalization) Technique2025 · 1 citations
  3. 3Lithoclast removal of an encrusted nephrostomy tube2010 · 5 citations
  4. 4Entrapped Malecot Nephrostomy Tube: Etiology and Management1995 · 16 citations
  5. 5Safe Removal of an Encrusted Nephrostomy Tube Using a Vascular Sheath: A Technique Revisited2013 · 8 citations