April 26, 2026European Heart Journal87 citationsOpen Access

Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation

View Full Paper
MTMakoto Takano

Key Result

Sirolimus-eluting stents demonstrated delayed neointimal coverage and slower thrombus disappearance compared to bare metal stents at 6 months post-implantation.

Key Points

  • To compare neointimal coverage and thrombus persistence between sirolimus-eluting and bare metal stents after 6 months.
  • Randomized trial involving 46 patients with angina and acute coronary syndrome treated with SESs and BMSs.
  • Angioscopy was used to evaluate neointimal coverage and thrombus presence immediately and at 6 months after stenting.
  • Neointimal coverage was graded on a scale assessing visibility of stent struts.
  • Average neointimal coverage was lower in SESs compared to BMSs (edge: 1.4 vs. 1.9, body: 1.0 vs. 1.8, overlapping: 0.6 vs. 1.8; P<0.0001 for edge/body, P=0.0069 for overlapping).
  • Persistence of thrombus was significantly higher in SESs (86%) than in BMSs (29%; P=0.031).

Structured PICO

Do sirolimus-eluting stents delay neointimal coverage and thrombus disappearance compared to bare metal stents at 6 months?

P
Population
Patients evaluated after a 6-month stent implantation
I
Intervention
Sirolimus-eluting stents (SES)
C
Comparator
Bare metal stents (BMS)
O
Outcome
Neointimal stent coverage and persistence of thrombus evaluated by angioscopysurrogate

Sirolimus-eluting stents demonstrate delayed healing and slower thrombus resolution compared to bare metal stents at 6 months, highlighting potential mechanisms for late stent thrombosis.

Abstract

AIMS: The neointimal coverage and intracoronary thrombi within stented segments at 6 months after implantation between sirolimus-eluting stents (SESs) and bare metal stents (BMSs) were compared by direct visualization using angioscopy. METHODS AND RESULTS: Forty-six patients (36 stable angina and 10 acute coronary syndrome) were treated with 33 SESs and 33 BMSs. Immediately after and 6 months after stenting, each of the stented segments, edge body, and overlapping segment were observed by angioscopy and the grade of neointimal coverage over the stents was classified as 0: absent neointima, 1: visible struts through thin neointima, or 2: invisible struts. The existence of thrombi was also evaluated. The average grade of the neointimal coverage at 6 months follow-up was lower in the SES than that in the BMS (edge: 1.4+/-0.7 vs. 1.9+/-0.2, body: 1.0+/-0.5 vs. 1.8+/-0.5, overlapping segment: 0.6+/-0.7 vs. 1.8+/-0.5; P<0.0001, P<0.0001, P=0.0069, respectively). The frequency of persistence of thrombus was significantly higher in the SESs than that in the BMSs (86 vs. 29%, respectively; P=0.031). CONCLUSION: The present study suggested a delayed neointimal stent coverage and slower thrombus disappearance process in the SESs in comparison to the BMSs.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Makoto Takano (2006) studied this question. Sirolimus-eluting stents demonstrated delayed neointimal coverage and slower thrombus disappearance compared to bare metal stents at 6 months post-implantation.

synapsesocial.com/papers/69ee2ce79de2ebe49371005dhttps://doi.org/10.1093/eurheartj/ehl181