PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 27, 20260 citationsOpen Access

Executable Gauge-Running Hardening of the QDL–SO10–1 Grand-Unification Benchmark: Revised Coupling Closure, Calibrated Threshold Targets, and Proton-Decay Rescaling

View Full Paper
JBJames D. Bourassa

Key Points

  • This paper aims to execute gauge-running hardening for the QDL–SO10–1 benchmark, refining earlier predictions.
  • Introduced Version 0.2 executable results to adjust gauge-running hardening targets.
  • Revised coupling target based on mean Pati-Salam inverse coupling values.
  • Documented calibrated high-scale threshold targets and proton-decay lifetimes.
  • Achieved revised coupling target αU,v0.2−1=44.501718, significantly improving calibration.
  • Documented calibrated residual at 2.57×10−7, indicating enhanced accuracy.
  • Rescaled central proton-decay lifetime to 3.324041×10^{35} years, reflecting gauge-mediated lifetime scaling.

Abstract

The QDL–SO10–1 grand-unification sequence defines a closure-first SO (10) -compatible benchmark within the Quantized Dimensional Ledger (QDL) program. The first three papers in the sequence established a fixed numerical benchmark, its low-energy phenomenology, and a robustness/failure-mode audit. The present paper begins the executable hardening sequence. This paper provides the v0. 2 executable gauge-running hardening result for QDL–SO10–1. The v0. 1 artifact showed that the original declared target αU−1=25. 6U^-1=25. 6αU−1=25. 6 is not reproduced by the minimal pure-gauge executable scaffold, yielding an old-target RMS residual of 18. 92788118. 92788118. 927881. The v0. 2 artifact resolves the dominant residual by revising the executable coupling target to the mean Pati–Salam inverse coupling at MUMUMU, giving αU, v0. 2−1=44. 501718ₔ, ₕ₀. ₂^-1=44. 501718αU, v0. 2−1=44. 501718 and αU, v0. 2=0. 022471ₔ, ₕ₀. ₂=0. 022471αU, v0. 2=0. 022471. The remaining channel splittings are recorded as calibrated high-scale threshold targets: λ4CU, v0. 2=−1. 284227₄₂^U, v0. 2=-1. 284227λ4CU, v0. 2=−1. 284227, λ2LU, v0. 2=+0. 950018₂₋^U, v0. 2=+0. 950018λ2LU, v0. 2=+0. 950018, and λ2RU, v0. 2=+0. 334210₂ₑ^U, v0. 2=+0. 334210λ2RU, v0. 2=+0. 334210. With these revised values, the calibrated residual is 2. 57×10−72. 5710^-72. 57×10−7. Proton-decay exposure is also rescaled because gauge-mediated lifetimes scale approximately as τp∝αU−2ₚU^-2τp∝αU−2, moving the central p→e+π0p e^+⁰p→e+π0 lifetime to 3. 324041×10353. 32404110^353. 324041×1035 yr. This is a calibrated executable closure result, not yet a full scalar-derived resolution. The next artifact, v0. 3, must derive the calibrated threshold offsets from explicit SO (10) →→Pati–Salam scalar multiplets and Dynkin-index weighted threshold corrections. The final all-inclusive QDL–SO10–1 perspective is deferred until the executable hardening sequence is complete.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

James D. Bourassa (2026) studied this question.

synapsesocial.com/papers/69eefd43fede9185760d4049https://doi.org/10.5281/zenodo.19773261
Ask AI
Helpful
Bookmark
Share
View Full Paper