PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 29, 2026ASME Journal of Heat and Mass Transfer0 citations

Transient Characteristic and Performance of Novel Loop Heat Pipe

View Full Paper
APAfifa PramesywariMKMukhsinun Hadi KusumaBKBerkah Fajar Tamtomo Kiono

Key Points

  • The research aims to evaluate the performance and transient characteristics of a novel loop heat pipe.
  • Analyzed effects of heat load, filling ratio, and inclination angle on LHP performance.
  • Conducted experiments with water tank temperatures ranging from 35°C to 65°C.
  • Maintained a constant pressure and cooled the condenser with air.
  • Achieved lowest thermal resistance of 0.0338 ± 0.007 °C/W at optimal conditions.
  • Demonstrated stable natural circulation and effective passive heat exchange.
  • Confirmed rapid and stable start-up under tested conditions.

Abstract

Abstract A novel loop heat pipe (LHP) model was proposed as a passive heat absorption and dissipation technology to address thermal challenges. This LHP featured a wick of copper capillary tubes without a compensation chamber, and utilized a reduced-diameter liquid line and casing wick. This study investigated the transient characteristics and performance of the LHP by analyzing the effects of heat load, filling ratio, inclination angle, and mapped Natural Circulation Stability (NCS) in Phase-Change Number-nd mapped Natural Circulation Stability Subcooling Number space to determine whether the proposed geometry and operating range remained stable. The effectiveness of the LHP as a heat exchanger was also assessed in comparison to conventional heating methods. Experiments were conducted by varying water tank temperatures as a heat load of 35°C to 65°C, filling ratios of 40% to 120%, and inclination angles of 0° to 5°. The condenser was cooled using air at a constant velocity, while the initial pressure of 5332.88 Pa was maintained before the Acetone as LHP working fluid charged. Experiment results showed that the optimal configuration at a higher heat load, an 80% filling ratio, and a 5° inclination angle with a PVC socket achieved the fastest and most stable start-up with the lowest thermal resistance of 0.0338 ± 0.007 °C/W, NCS analysis confirmed stable circulation, and achieved efficient and uniform heat distribution with enhanced thermal stability. These findings demonstrate that the proposed LHP achieved rapid, stable start-up, stable natural circulation, and effective passive heat exchange.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pramesywari et al. (2026) studied this question.

synapsesocial.com/papers/69f154e0879cb923c49451c5https://doi.org/10.1115/1.4071762
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Numerical study and parametric analysis of thermo-hydraulic behavior in a flat loop heat pipe at system scale2024
  2. 2Modeling, Design, and Optimization of Loop Heat Pipes2024 · 11 citations
  3. 3Experimental investigation of a 10 kW-class flat-type loop heat pipe for waste heat recovery2024 · 5 citations
  4. 4Advanced loop heat pipe application for cooling high power LED lights2024 · 8 citations
  5. 5Comparison Study of Novel Flat Evaporator Loop Heat Pipes with Different Types of Condensation Pipeline2025