PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 1, 1988Cardiovascular Research120 citations

Application of a time varying elastance model to right ventricular performance in man

View Full Paper
LDLouis J. Dell’ItaliaRWRichard A. Walsh

Structured PICO

P
Population
9 patients with normal coronary anatomy and ventricular function
I
Intervention
Simultaneous high fidelity pressure, flow-velocity, and biplane cineventriculographic volumes during atrial pacing at 93(SD5) beats-min-1, partial autonomic blockade, and pharmacologically altered ventricular loading
O
Outcome
Maximum time varying elastance (Emax) and its correlation with other right ventricular end systolic pressure-volume relationssurrogate

In normal human subjects, right ventricular systolic function can be approximated using a time varying elastance model, with maximum pressure/volume ratio and peak pressure/minimum volume systematically estimating Emax.

Abstract

To evaluate instantaneous right ventricular pressure-volume relations we studied nine patients with normal coronary anatomy and ventricular function with simultaneous high fidelity pressure, flow-velocity, and biplane cineventriculographic volumes (60 frames.s-1) during atrial pacing at 93(SD5) beats-min-1, partial autonomic blockade, and pharmacologically altered ventricular loading. The maximum time varying elastance, Emax, was defined as the maximum slope of isochronal, simultaneous pressure-volume data points derived by linear regression analysis from three loading conditions. The slope of the non-isochronal maximum pressure/volume ratio, pressure at minimum volume, end ejection pressure/volume, and peak right ventricular pressure/minimum volume were also derived from the three loading conditions. The mean slope for Emax was 1.30(0.84) mm Hg.ml-1 (range 0.62-2.87) and the volume axis intercept at zero pressure (Vo) was 46(21) ml (range 24-89 ml). Time dependent Emax was characterised by a series of parallel shifting lines of best fit with large changes in Vo in addition to changes in the slope of the pressure volume relations. Only maximum pressure/volume ratio and peak pressure/minimum volume were linearly related to Emax (r = 0.82 and 0.84 respectively, p = 0.05) while pressure at minimum volume and end ejection pressure/volume did not correlate with Emax. We conclude that in normal human subjects (1) right ventricular systolic function may be approximated using a time varying elastance model characterised by a time dependent Vo; (2) end systolic pressure-volume relations using maximum pressure/volume ratio and peak pressure/minimum volume systematically estimate Emax; and (3) other right ventricular end systolic pressure-volume relations near end ejection bear no obvious relation to Emax because of the wide temporal separation between peak systolic elastance and end ejection in this chamber.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dell’Italia et al. (1988) studied this question.

synapsesocial.com/papers/69f29d9951fe1e6e26efb8b9https://doi.org/10.1093/cvr/22.12.864
Ask AI
Helpful
Bookmark
Share
View Full Paper