April 30, 2026Journal of Ophthalmology0 citationsOpen Access

Accuracy of Toric Intraocular Lens Implantation Using Three‐Random‐Point Marking Method: A Prospective Pilot Study

View Full Paper
SCShuilian ChenYLYiliang LiuFLFulong Luo

Key Points

  • This study compares the accuracy of two marking methods for toric IOL positioning during cataract surgery.
  • Prospective pilot study with 60 eyes of 54 patients undergoing cataract surgery.
  • Randomized into three groups based on pupil size and doctor's experience.
  • Comparison of axis deviations using three‐random‐point marking method and slit‐lamp horizontal meridian marking method.
  • Significant differences observed in axis deviations between methods in all groups.
  • TRP method showed lower deviation compared to SHM method in novice and experienced doctors.
  • Statistical analysis indicated p < 0.01 and p < 0.05 for various groups.

Abstract

Introduction This study aimed to compare the accuracy of three‐random‐point (TRP) marking method with the slit‐lamp horizontal meridian (SHM) marking method by using an image‐guided system in the positioning of a toric intraocular lens (IOL). Materials and Methods A total of 60 eyes of 54 patients who underwent cataract surgery were prospectively randomized into 3 groups (each group included 20 eyes: Group 1, novice doctor and dilated pupil patient; Group 2, novice doctor and small pupil patient; and Group 3, experienced doctor and small pupil patient). Every patient was marked three points (horizontal two points and random third point) in corneal limbus with a staining blunt needle and then measured by the iTrace system. The axis deviations from the SHM method (axis A, horizontal two points method) and the TRP method (axis B, three points method) were measured by the digital image‐guided navigation system. Results The axis deviations of each group showed a significant difference between the SHM and TRP marking methods (Group 1: SHM method: 3.05° ± 2.58° and TRP method: 0.85° ± 0.93°, p < 0.01; Group 2: SHM method: 2.15° ± 2.35° and TRP method: 1.05° ± 1.57°, p < 0.05; and Group 3: SHM method: 1.00° ± 1.84° and TRP method: 0.45° ± 1.23°, p < 0.05). Conclusions The TRP marking method using the iTrace aberrometer was found to be more effective and more accurate than SHM marking method in the positioning of toric IOLs before surgery. Trial Registration: Chinese Clinical Trial Registry: ChiCTR2600121114

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Chen et al. (2026) studied this question.

synapsesocial.com/papers/69f2a42a8c0f03fd67763201https://doi.org/10.1155/joph/7948866
Ask AI
Helpful
Bookmark
Share
View Full Paper