PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 30, 2026Foods0 citationsOpen Access

A Cyanide-Free UHPLC-MS/MS Workflow for the Analysis of Major Cobalamin Vitamers in Foods

View Full Paper
FWFengen WangLCLi CaoMDMin Ding

Key Points

  • This research aims to develop a cyanide-free method for determining cobalamin vitamers in foods, preserving their integrity.
  • Developed a cyanide-free UHPLC-MS/MS workflow for food analysis.
  • Evaluated effects of light, temperature, and cleanup procedures on vitamer integrity.
  • Implemented immunoaffinity and Oasis HLB solid-phase extraction for sample preparation.
  • Demonstrated good chromatographic separation and excellent linearity (R2 > 0.999).
  • Detected no target cobalamins in plant-derived foods, while high levels found in animal liver and oysters.
  • Methylcobalamin and Adenosylcobalamin showed significant light sensitivity during analysis.

Abstract

Accurate determination of cobalamin vitamers in foods remains analytically challenging because conventional cyanidation-based methods convert native cobalamins into cyanocobalamin (CNCbl) and may distort their original distribution. In this study, a cyanide-free UHPLC-MS/MS workflow was developed for the analysis of major cobalamin vitamers in foods, with particular emphasis on preserving native forms during sample preparation. Light, temperature, and cleanup procedures were systematically evaluated. Methylcobalamin (MeCbl) and adenosylcobalamin (AdoCbl) showed pronounced light sensitivity, whereas red-light handling better preserved vitamer integrity during pre-analytical operations. A tandem cleanup procedure combining immunoaffinity and Oasis HLB solid-phase extraction improved extract cleanliness in complex food matrices. The workflow showed good chromatographic separation and excellent linearity (R2 > 0.999). The validated limits of detection were 0.5 μg/kg for CNCbl, 1.0 μg/kg for AdoCbl, and 0.75 μg/kg for MeCbl. Application to food samples showed no detectable target cobalamins in the tested plant-derived foods, whereas animal liver and oyster samples showed comparatively high levels of the target cobalamin vitamers, with AdoCbl predominating in liver. The proposed workflow may serve as a practical cyanide-free option for exploratory or comparative native-vitamer analysis of CNCbl, AdoCbl, and MeCbl in foods within the current validation scope, particularly when full sets of matched isotope-labeled standards are not readily available.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wang et al. (2026) studied this question.

synapsesocial.com/papers/69f2a4f18c0f03fd67764213https://doi.org/10.3390/foods15091506
Ask AI
Helpful
Bookmark
Share
View Full Paper