PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 6, 2026National Journal of Maxillofacial Surgery0 citations

Evaluation of stress and strain distribution in and around orthodontic extra-alveolar mini-implants in the Infrazygomatic Crest region during retraction of teeth: A Finite Element Method Study

View Full Paper
DSDiptiman ShuklaTCT P ChaturvediSPS K Panda

Key Points

  • This research evaluates stress distribution in orthodontic mini-implants during tooth retraction.
  • Finite element analysis was used to simulate stress and strain around mini-implants.
  • Two 3D FEM models were created to test different insertion angles and force directions.
  • A static load of 3 N was applied from three directions over four defined angles.
  • The highest von Mises stress was found at the implant neck and adjacent cortical bone.
  • Lower insertion angles (40°–50°) resulted in more uniform stress distribution.
  • Maximum von Mises stresses were 20.05 MPa for the implant and 10.94 MPa in cortical bone.

Abstract

Introduction: Precise anchorage control is critical for predictable orthodontic tooth movement. Extra‐alveolar mini-implants in the infrazygomatic crest (IZC) region benefit from robust cortical bone; however, the distribution of stress—and thus long-term stability—is heavily influenced by implant design, insertion angle, and force orientation. Finite element analysis (FEA) offers the robust method for simulating these biomechanical interactions. Objective: The study aims to evaluate von Mises stress distribution patterns in mini-implants and surrounding bone at various placement angles and force directions in the IZC region using finite element method (FEM), with the goal of determining the configuration that minimizes peak stress and optimizes load transfer. Material and Methods: Two 3D FEM models were generated to simulate orthodontic force applications on mini-implants with different geometric parameters and insertion angles. A static load of 3 N was applied to the implant head from three directions (horizontal, oblique, vertical) over four defined insertion angles. FE simulations were performed using Ansys Workbench v24 (a software developed and manufactured by ANSYS, Inc., Pennsylvania, USA however, both designs operate within the safe fatigue limits of titanium. These findings underscore the utility of FEA in optimizing implant design and surgical protocols for clinical success.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Shukla et al. (2026) studied this question.

synapsesocial.com/papers/69faa2b504f884e66b533400https://doi.org/10.4103/njms.njms_40_25
Ask AI
Helpful
Bookmark
Share
View Full Paper